Structural calculation report - bearing check error
구조계산서 9. 교좌부검토 에서 Hx2, Hy2 에 수평력-탄성지진력중 "최대값"을 사용해야 하는데 Shoe 5번 값만 사용하게 되어있는것 같습니다. Shoe 5번의 수평력은 항상 최대값이 아닙니다. 첨부한 엑셀 파일을 검토하여 주시길 바랍니다.
Answer
안녕하세요. 한길아이티입니다. 교좌부검토시 교대의 경우 교축직각방향의 수평력이 가장 큰 교량받침을 기준으로 검토하고 있습니다. 해당파일과 같은 오류가 발생하는 경우가 있어 수정하였습니다. 금일자 패치에 적용하도록 하겠습니다. 감사합니다.
Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #187216 | Pier bearing dimensions | 20 | 2004-07-28 |
| Answered | AAbutPier | #187206 | Inquiry about abutments and piers | 29 | 2004-07-27 |
| Answered | AAbutPier | #187205 | Reposting | 55 | 2004-07-27 |
| Answered | AAbutPier | #187200 | Please check the quantities | 60 | 2004-07-27 |
| Answered | AAbutPier | #187198 | Question about shoe specification input | 33 | 2004-07-27 |
| Answered | AAbutPier | #187209 | Inquiry about wing wall end EL values | 23 | 2004-07-27 |
| Answered | AAbutPier | #187204 | Patch file | 44 | 2004-07-27 |
| Answered | AAbutPier | #187196 | Request to change pile length from 5.9 to 4.6 | 40 | 2004-07-27 |
| Answered | AAbutPier | #187191 | Please check seismic horizontal force calculation for elastomeric bearings | 80 | 2004-07-26 |
| Answered | AAbutPier | #187189 | When checking pier design | 49 | 2004-07-26 |
| Answered | AAbutPier | #187184 | SAP error in seismic analysis for IPC bridge | 50 | 2004-07-26 |
| Answered | AAbutPier | #187193 | Quantity report output problem | 46 | 2004-07-26 |
| Answered | AAbutPier | #187183 | Distribution bars look wrong in abutment wing wall reinforcement drawing | 41 | 2004-07-26 |
| Answered | AAbutPier | #187182 | When outputting the pier calculation report | 19 | 2004-07-25 |
| Answered | AAbutPier | #187181 | In the pier structural calculation report | 55 | 2004-07-24 |
| Answered | AAbutPier | #187180 | Internal application error | 46 | 2004-07-24 |
| Answered | AAbutPier | #187173 | Jinhwa seismic: reposting | 16 | 2004-07-24 |
| Answered | AAbutPier | #187175 | Whether column rebar ratio is applied | 76 | 2004-07-23 |
| Answered | AAbutPier | #187174 | Structural calculation report - bearing check error · Currently viewing | 40 | 2004-07-23 |
| Answered | AAbutPier | #187170 | Approach slab | 16 | 2004-07-23 |