AnsweredAAbutPierQ&A #1272502014-06-25 01:25 · Views 184

Maximum axial force gives N.G in column analysis

이유를 잘 모르겠습니다. 계산서 출력시에도 잘못된 부분은 없는거 같은데 N.G가 뜨네요.

Attached images 1
Answer

안녕하세요. 한길아이티입니다. 질의하신 사항은 KCI2012 가 적용되었기에 확대 모멘트 계수 가 1.4 를 초과하는 경우에는 N.G 를 표시하도록 구성되어져 있습니다. 감사합니다.

Attached images 2

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#196189Cross tie rebar quantity error142005-11-18
AnsweredAAbutPier#196184Distance from parapet to shoe center282005-11-18
AnsweredAAbutPier#196181Seismic pile reactions in pier foundation design with cast-in-place piles392005-11-18
AnsweredAAbutPier#196170Column design for a sway (unbraced) structure502005-11-18
AnsweredAAbutPier#196183Pile load test quantity292005-11-18
AnsweredAAbutPier#196182Coefficient of horizontal subgrade reaction312005-11-18
AnsweredAAbutPier#196179When changing rebar details382005-11-18
AnsweredAAbutPier#196174Changing main rebar to two layers652005-11-18
AnsweredAAbutPier#196161Temperature load calculation for pier at expansion joint seems wrong902005-11-18
AnsweredAAbutPier#196158Drawing generation532005-11-18
AnsweredAAbutPier#196155Pier bearing seat location mismatch352005-11-18
AnsweredAAbutPier#196152Follow-up to phone inquiry682005-11-18
AnsweredAAbutPier#196150About the stability index632005-11-18
AnsweredAAbutPier#196149Shoe tonnage is entered incorrectly892005-11-18
AnsweredAAbutPier#196142Additional question on 18970642005-11-18
AnsweredAAbutPier#196140About the left wing wall reinforcement drawing of the abutment712005-11-18
AnsweredAAbutPier#196129Spread footing thickness check472005-11-17
AnsweredAAbutPier#196163Rounding the bottom of the coping end112005-11-17
AnsweredAAbutPier#196135Number of bearings per girder702005-11-17
AnsweredAAbutPier#196121Cast-in-place pile rebar ratio592005-11-17
Sign in to ask