AnsweredAAbutPierQ&A #1245912014-02-05 23:23 · Views 198

Question about pier coping step

FCM과 일반빔구간에 위치한 교각(P9) 코핑 단차가 원활하게 진행이 되지 않아 문의 드립니다. 감사합니다.

Answer

안녕하세요. 한길아이티입니다. 질의하신 사항은 두부보 종방향 변단면 설칭에 관련된 사항입니다. 단면도제원에서 두부보 종방향 변단면 선택, ctw 입력한후 교좌면 제원에서 권고안후 적용 버튼 누르시면 두부보 종방향 변단면이 작성됩니다. 테스트 동영상 첨부합니다. 감사합니다.

Attached images

2 attached files · Only the person who posted and our support staff can open them.

Sign in if this is your post

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#193034Please check the cement milk quantity for piles672005-07-05
AnsweredAAbutPier#193032About horizontal force during earthquakes672005-07-05
AnsweredAAbutPier#193045Cannot display slanted text in Aboard622005-07-05
AnsweredAAbutPier#193044Company name appears garbled in the drawing title block322005-07-05
AnsweredAAbutPier#193026Wing wall reinforcement detailing issue492005-07-05
AnsweredAAbutPier#193017Internal program error282005-07-04
AnsweredAAbutPier#193025Question about ALine382005-07-04
AnsweredAAbutPier#193022About the input items192005-07-04
AnsweredAAbutPier#193020Question about abutment wing walls462005-07-04
AnsweredAAbutPier#193010Question about input items182005-07-04
AnsweredAAbutPier#193007Suggestion on wing wall design check312005-07-03
AnsweredAAbutPier#193005About foundation distribution rebar382005-07-02
AnsweredAAbutPier#192997Error in pier cap rebar quantity check682005-07-02
AnsweredAAbutPier#192986Bearing location in abutment general drawing differs from cross-section input452005-07-01
AnsweredAAbutPier#192985Question about pier calculation section272005-07-01
AnsweredAAbutPier#192990To the HanGil representative712005-07-01
AnsweredAAbutPier#192976Please check the abutment front view142005-07-01
AnsweredAAbutPier#192970Clicking Next in the input window152005-06-30
AnsweredAAbutPier#192979Question about the structural calculation report272005-06-30
AnsweredAAbutPier#192973Bearing pedestal concrete252005-06-30
Sign in to ask