Skip to content
AnsweredAAbutPierQ&A #1221732013-10-17 19:17 · Views 190

Why earth pressure differs slightly under identical conditions

교대검토시 3.하중산정 2)배면토에 의한 토압 안정검토시와 단면검토시에 평상시와 지진시 모두 토압값이 미미하게 차이나는 이유에 문의드립니다 첨부하였습니다만 종점교대 끼리 비교하였을경우에 AA방향 평상시 토압 (H = 7.800 m) Pa = 1/2 x Ka x γ x H²x cos(δ) = 1/2 x 0.271 x 20.000 x 7.800² x cos(0.000) = 164.876 kN __________________ BB방향 - 평상시 토압 (H = 7.800 m) Pa = 1/2 x Ka x γ x H²x cos(δ) = 1/2 x 0.271 x 20.000 x 7.800² x cos(0.000) = 164.886 kN 감사합니다.

Answer

안녕하세요. 한길아이티입니다. 교대 높이를 m단위로 소수점 셋째자리 까지만 표현하기 때문에 양쪽 교대가 7.800m 로 표현되고 있습니다. 그러나, [개인정보] 교대의 실제 높이는 7.80022m 입니다. 이 높이를 대입해서 계산해 보면 계산된 결과가 타당하다고 판단됩니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#190216Calculation of section forces in the heel512005-01-17
AnsweredAAbutPier#190212About bearing seat for PSC beam702005-01-17
AnsweredAAbutPier#190208When checking the bearing seat?392005-01-17
AnsweredAAbutPier#190204Pier cap beam reinforcement562005-01-17
AnsweredAAbutPier#190214About pier spread foundation calculation682005-01-17
AnsweredAAbutPier#190213About PSC beam432005-01-17
AnsweredAAbutPier#190201About the abutment foundation172005-01-16
AnsweredAAbutPier#190196PSC continuous bridge452005-01-15
AnsweredAAbutPier#190195About pier calculation report output152005-01-15
AnsweredAAbutPier#190194Please fix abutment wing wall reinforcement error172005-01-15
AnsweredAAbutPier#190189Slab plan262005-01-15
AnsweredAAbutPier#190183File322005-01-14
AnsweredAAbutPier#190181Drawing generation292005-01-14
AnsweredAAbutPier#190186Applying ALINE to light rail562005-01-14
AnsweredAAbutPier#190177About unseating prevention devices722005-01-14
AnsweredAAbutPier#190175Approach slab width change by wing wall angle652005-01-14
AnsweredAAbutPier#190178About pier coping632005-01-13
AnsweredAAbutPier#190161Question about abutment seismic input452005-01-13
AnsweredAAbutPier#190159Abutment wing wall reinforcement drawing642005-01-13
AnsweredAAbutPier#190164Applying a longitudinally variable section to a pier652005-01-12
Sign in to ask