Calculation result N.G
벽체 검토에서 ng가 나왔습니다. 4/3as 이상 배치되었는데 NG네요~ 확인 부탁드립니다.
Answer
안녕하세요. 한길아이티입니다. 계산서를 출력해보시면 사용철근비가 수축온도철근비보다 작아 NG가 발생하고 있습니다. 4/3as에 대한 KCI 6.3.2 기준은 최소철근비에 대한 기준이며 수축온도철근비는 이와는 별도로 판단하고 있습니다. 기초자료설정 - 철근비 검토 탭에서 [인장철근에 대한 수축온도철근비 검토]를 체크해제하신다면 해당검토는 제외하므로 참고하시기 바랍니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #189508 | *** - please check | 82 | 2004-12-07 |
| Answered | AAbutPier | #189505 | Question about wing wall haunch | 27 | 2004-12-07 |
| Answered | AAbutPier | #189497 | Question about abutment rebar summary | 20 | 2004-12-07 |
| Answered | AAbutPier | #189482 | *** - please check | 21 | 2004-12-06 |
| Answered | AAbutPier | #189496 | When entering sections | 8 | 2004-12-06 |
| Answered | AAbutPier | #189475 | Borehole log not generated after upgrade | 30 | 2004-12-05 |
| Answered | AAbutPier | #189470 | About additional tie reinforcement | 38 | 2004-12-04 |
| Answered | AAbutPier | #189474 | Railway bridge with 3-span PSC beams | 19 | 2004-12-04 |
| Answered | AAbutPier | #189464 | *** Pier reinforcement drawing | 14 | 2004-12-04 |
| Answered | AAbutPier | #189466 | Bridge with combined and separated up/down lanes | 47 | 2004-12-03 |
| Answered | AAbutPier | #189451 | Text not visible in drawings | 26 | 2004-12-03 |
| Answered | AAbutPier | #189449 | *** - *** inquiry (reinforcement drawing) | 26 | 2004-12-03 |
| Answered | AAbutPier | #189452 | Core confinement reinforcement in hollow piers | 74 | 2004-12-03 |
| Answered | AAbutPier | #189439 | Error after update - 1 | 30 | 2004-12-02 |
| Answered | AAbutPier | #189434 | *** - *** inquiry | 22 | 2004-12-02 |
| Answered | AAbutPier | #189448 | Entering inner haunch for pi-shaped pier | 23 | 2004-12-02 |
| Answered | AAbutPier | #189429 | Wing wall rebar details differ in abutment reinforcement drawing | 26 | 2004-12-02 |
| Answered | AAbutPier | #189426 | Issue seems not fixed by the patch | 13 | 2004-12-02 |
| Answered | AAbutPier | #189436 | Error after update | 20 | 2004-12-02 |
| Answered | AAbutPier | #189418 | Setting abutment main rebar to CTC100 | 5 | 2004-12-02 |