Formula error in section properties of seismic structural calculation report
마찬가지로 아래의 내진구조계산서 단면특성 Sheet에서 행108의 아래의 수식이 "x" 아니라 "+"로 오류 확인 바랍니다. I22=∑Io + ∑AsZ² = 0.0120 x 0.0024 = 0.0144572 m⁴ +
Answer
안녕하세요. 한길아이티입니다. 수정하였습니다. 금일자 패치에 적용하겠습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #186880 | About x1 and x2 in rebar detail drawing | 5 | 2004-07-08 |
| Answered | AAbutPier | #186870 | Please reply | 18 | 2004-07-08 |
| Answered | AAbutPier | #186866 | Internal application error occurs | 10 | 2004-07-08 |
| Answered | AAbutPier | #186854 | Request for reply from HanGil staff | 5 | 2004-07-07 |
| Answered | AAbutPier | #186853 | Bearing seat rebar input | 11 | 2004-07-07 |
| Answered | AAbutPier | #186852 | Shoe position recognized incorrectly | 7 | 2004-07-07 |
| Answered | AAbutPier | #186847 | Loads from the superstructure | 22 | 2004-07-07 |
| Answered | AAbutPier | #186840 | About the approach slab... | 9 | 2004-07-07 |
| Answered | AAbutPier | #186871 | About beam layout | 23 | 2004-07-07 |
| Answered | AAbutPier | #186868 | Seismic analysis modeling output values not applied even after reloading | 33 | 2004-07-07 |
| Answered | AAbutPier | #186867 | Text label error in column section of pier reinforcement drawing | 27 | 2004-07-07 |
| Answered | AAbutPier | #186865 | Closed stirrup rebar details in pier reinforcement drawing | 34 | 2004-07-07 |
| Answered | AAbutPier | #186857 | Request for reply from HanGil staff 2 | 24 | 2004-07-07 |
| Answered | AAbutPier | #186856 | Request for reply from HanGil staff 2 | 15 | 2004-07-07 |
| Answered | AAbutPier | #186855 | Request for reply from HanGil staff 2 | 17 | 2004-07-07 |
| Answered | AAbutPier | #186846 | Formula error in section properties of seismic structural calculation report · Currently viewing | 8 | 2004-07-07 |
| Answered | AAbutPier | #186844 | Error when calculating section properties in seismic structural calculation report | 7 | 2004-07-07 |
| Answered | AAbutPier | #186841 | Error when calculating section properties in seismic structural calculation report | 12 | 2004-07-07 |
| Answered | AAbutPier | #186839 | Thanks, I received the answer... | 24 | 2004-07-07 |
| Answered | AAbutPier | #186837 | Follow-up on our phone call | 21 | 2004-07-07 |