Skip to content
AnsweredAAbutPierQ&A #1190892013-06-13 00:09 · Views 409

Qb check location

교대 지반반력 산정에서 4.전면저판의 단면력 계산입니다. 여기서 Qa, Qb로 표현된 전단검토위시와 모멘트 검토위치시가 있는데 Qa는 설계환경-설계선택사항-기초의 전단검토시 위험단면 위치로 결정합니다. Qb의 위치와 거리는 어떻게 검토가 된건가요?

Attached images 1
Answer

안녕하세요. 한길아이티입니다. 질의하신 사항은 전단검토위치입니다. 해당 위치를 캡쳐화면으로 첨부합니다. 감사합니다.

Attached images 2

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#187630Hollow pier P-M interaction diagram output error382004-08-20
AnsweredAAbutPier#187626About rebar input for bearings92004-08-20
AnsweredAAbutPier#187625Ground data mismatch in abutment foundation ground information392004-08-20
AnsweredAAbutPier#187629Approach slab drawing generation error422004-08-20
AnsweredAAbutPier#187622Incorrect dimensions shown for the uplift restraint device on abutment back face342004-08-20
AnsweredAAbutPier#187621Foundation design in pier calculation report212004-08-20
AnsweredAAbutPier#187617Uploading the file discussed by phone on deep beam shear design62004-08-20
AnsweredAAbutPier#187614Guyeong Bridge 2 file82004-08-19
AnsweredAAbutPier#187612Reactions in abutment structural calculation report differ from input values432004-08-19
AnsweredAAbutPier#187611Output does not work262004-08-19
AnsweredAAbutPier#187604Drawing generation error332004-08-19
AnsweredAAbutPier#187603Shear rebar arrangement412004-08-19
AnsweredAAbutPier#187605Pier foundation342004-08-19
AnsweredAAbutPier#187602About the pier calculation report602004-08-19
AnsweredAAbutPier#187595Error marks appear in the input tree, please take a look352004-08-19
AnsweredAAbutPier#187598Question about merging files532004-08-18
AnsweredAAbutPier#187590Structural calculation report - ultimate section forces in foundation design422004-08-18
AnsweredAAbutPier#187587Is substructure design possible after beam layout?422004-08-18
AnsweredAAbutPier#187586Pier structural calculation812004-08-18
AnsweredAAbutPier#187581Abutment structural calculation (parapet on approach slab side)352004-08-18