Skip to content
AnsweredAAbutPierQ&A #1139162012-10-25 19:39 · Views 231

Abutment widening

질문사항을 첨부합니다..

Answer

안녕하세요. 한길아이티입니다. 첨부하신 자료를 바탕으로 답변드리며, 선형은 그대로 있고 우측으로 교대 추가길이가 발생한 사항은 선형참조 수동의 상태로 작업하셨기 때문으로 판단됩니다. 선형참조 자동으로 바꾼 후 작업하시면 선형의 좌측으로 추가거리가 발생하는 것을 확인하실수 있습니다. 테스트 파일 첨부합니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#181450Main rebar input issue692003-07-11
AnsweredAAbutPier#181445Drawing output problem!802003-07-11
AnsweredAAbutPier#181440Abutment ELV calculation basis and abutment ELV table values842003-07-10
AnsweredAAbutPier#181446Issue in reinforcement drawing852003-07-10
AnsweredAAbutPier#181438Please check pier EL.692003-07-10
AnsweredAAbutPier#181430Inquiry about shoe layout on T-type pier772003-07-10
AnsweredAAbutPier#181413Multi-column pier general drawing won't output702003-07-09
AnsweredAAbutPier#181404Please check the skewed abutment foundation692003-07-09
AnsweredAAbutPier#181389Question about APier1012003-07-08
AnsweredAAbutPier#181388Calculation report correction request for attachment in post 3537722003-07-08
AnsweredAAbutPier#181385Please recover this file too772003-07-08
AnsweredAAbutPier#181384Problem in abutment calculation report722003-07-08
AnsweredAAbutPier#181398Multi-column pier general drawing won't output612003-07-08
AnsweredAAbutPier#181372"Failed to open document" message appears772003-07-07
AnsweredAAbutPier#181368Analysis of attached file gives an error - why?942003-07-07
AnsweredAAbutPier#181366File won't open592003-07-07
AnsweredAAbutPier#181364Abutment with sloped slab982003-07-07
AnsweredAAbutPier#181349Abutment foundation input682003-07-04
AnsweredAAbutPier#181346Tie bar spacing in general zone of column reinforcement782003-07-04
AnsweredAAbutPier#181351Reinforcement drawing looks wrong972003-07-04
Sign in to ask