Skip to content
AnsweredAAbutPierQ&A #1850842004-03-12 20:58 · Views 46

Seismic

내진 sap200input 생성에서 좀 이상하네여 SPRING ADD= 306 U1= 77370 U2= 77370 U3= 65259 R1= 1396902 R2= 1396902 R3= 2939658 ADD= 312 U1= 0 U2= 0 U3= 0 R1= 0 R2= 0 R3= 0 값이 안들어감 ADD= 318 U1= 77370 U2= 77370 U3= 65259 R1= 1396902 R2= 1396902 R3= 2939658 ADD= 324 U1= 77372 U2= 77372 U3= 65235 R1= 1397143 R2= 1397143 R3= 2939180 ADD= 328 U1= 77370 U2= 77370 U3= 65259 R1= 1396902 R2= 1396902 R3= 293965 FRAME SECTION NAME=FOT02 TYPE=PRISM MAT=FOOT SH=R T= 8.00, 4.00 기초 폭 8mx8m NAME=FOT03 TYPE=PRISM MAT=FOOT SH=R T= 8.00, 4.00 NAME=FOT04 TYPE=PRISM MAT=FOOT SH=R T= 8.00, 4.00 NAME=FOT05 TYPE=PRISM MAT=FOOT SH=R T= 8.00, 4.00 NAME=FOT06 TYPE=PRISM MAT=FOOT SH=R T= 8.00, 4.00

Answer

안녕하세요. 한길아이티입니다. 검토 결과 설계하신 두번째 교각의 보링하단이 교각 기초하단보다 높게 입력이 되어있습니다. 즉, 교각 기초에 대한 보링데이타가 존재하지 않아서 발생한 현상입니다. 이 내용은 [교각입력>>단면도 제원]에서 를 선택하시면 확인하실 수 있습니다. 입력을 수정하시기 바랍니다. 기초폭에 대한 오류는 수정하였습니다. 금일(3/12) 18시 이전에 패치를 올리도록 하겠습니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#185135Abutment widening432004-03-17
AnsweredAAbutPier#185129Pier reinforcement drawing162004-03-17
AnsweredAAbutPier#185128Beam length and minimum distance to slab end when placing PSC beams472004-03-16
AnsweredAAbutPier#185123Seismic172004-03-16
AnsweredAAbutPier#185117Bearing locations overlap at pier...152004-03-16
AnsweredAAbutPier#185124Chapter 2 illustration: lateral distribution figure212004-03-16
AnsweredAAbutPier#185121Calculating additional wall height282004-03-16
AnsweredAAbutPier#185104When abutment widths differ at start and end...552004-03-14
AnsweredAAbutPier#185093Pier drawings222004-03-13
AnsweredAAbutPier#185091During seismic analysis...252004-03-13
AnsweredAAbutPier#185084Seismic · Currently viewing462004-03-12
AnsweredAAbutPier#185098Alignment check request912004-03-12
AnsweredAAbutPier#185076Earth pressure coefficient and friction angle in wall section check1052004-03-11
AnsweredAAbutPier#185069Bridge bearings482004-03-11
AnsweredAAbutPier#185063Inquiry about pier foundation calculation172004-03-10
AnsweredAAbutPier#185061[Question] Rebar fabrication and quantities in wing wall drawings312004-03-10
AnsweredAAbutPier#185052Pier calculation report won't print192004-03-10
AnsweredAAbutPier#185051Two-layer rebar at top of pier coping...162004-03-10
AnsweredAAbutPier#185045Crash after entering pier cap beam rebar262004-03-09
AnsweredAAbutPier#185050About drawings352004-03-09
Sign in to ask