Question in Korean (English title coming soon)
접속슬래브 배근시... 우측 배근이 이상합니다.확인좀 해주세요. 한가지더.. 날개벽이나.접속슬래브 전단철근 배근시. 간격재로 사용하여.. 철근상세를 3번으로 바꾸면... 철근 수량이 제대로 나오지를 않고 전단철근의 길이로 나옵니다. 철근상세를 ㄷ자형으로 바꾸면.. 길이도 맞게 바뀌어야 할거 같습니다.확인해주세요......
Answer
안녕하세요. 한길아이티입니다. 1. 접속 슬래브 배근 => 사각이 있는 접속 슬래브 배근시 우측에 오류를 확인하였습니다.수정후 패치에 적용토록 하겠습니다. 2. ㄷ자형 철근 변경 => 철근 타입을 변경시 각 해당 부재(a,b,c등)의 길이도 같이 변경하셔야 적용됩니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #268543 | Pile calculation report | 327 | 2026-09-28 |
| Answered | ACulvert | #268536 | Setting section changes in culvert | 166 | 2026-09-28 |
| Answered | ACulvert | #268524 | Design check not performed at wall center | 215 | 2026-09-27 |
| Answered | ACulvert | #268523 | Applying moving vehicle loads | 231 | 2026-09-27 |
| Answered | ACulvert | #268522 | Question about pile layout | 257 | 2026-09-23 |
| Answered | ACulvert | #268521 | Question about features | 128 | 2026-09-23 |
| Answered | ACulvert | #268510 | Question about joint check in Excel report output | 180 | 2026-09-22 |
| Answered | ACulvert | #268499 | Error in STM analysis of corner region | 139 | 2026-09-22 |
| Answered | ACulvert | #268471 | Launching the culvert program | 59 | 2026-09-18 |
| Answered | ACulvert | #268442 | All lines are displayed as dashed lines, what should I do? | 137 | 2026-09-17 |
| Answered | ACulvert | #268429 | Question about U-type underpass | 125 | 2026-09-17 |
| Answered | ACulvert | #268424 | Load position when applying railway loads to an underpass | 230 | 2026-09-17 |
| Answered | ACulvert | #268417 | Changing girder dimensions | 146 | 2026-09-17 |
| Answered | ACulvert | #268396 | Incorrect section check location for horizontal rebar | 173 | 2026-09-16 |
| Answered | ACulvert | #268376 | Question about segment settings for U-type retaining wall | 185 | 2026-09-15 |
| Answered | ACulvert | #268343 | Question about culvert drawing output | 126 | 2026-09-15 |
| Answered | ACulvert | #268337 | Inquiry about checking retaining-wall-type wing walls | 300 | 2026-09-14 |
| Answered | ACulvert | #268330 | About drawing output | 150 | 2026-09-14 |
| Answered | ACulvert | #268318 | Some blocks not displayed | 135 | 2026-09-14 |
| Answered | ACulvert | #268317 | Tank load for surcharge and moving loads | 334 | 2026-09-14 |