Question in Korean (English title coming soon)
온도하중적용시 바닥판과 기타부분에 대한 온도차에의한 온도하중이 적용되지 않는데요.. (철도설계기준 철도교편 p34) 검토부탁드립니다
Answer
안녕하세요. 한길아이티입니다. 설계기준에 있는 사항은 직사광선이 상부슬래브에 쏘일때의 영향을 고려하라는 내용입니다. 이 사항은 이미 적용된 내용입니다. 다만 철도암거의 경우 상면에 도상구조가 있어 직사광선이 상부슬래브 상면에 직접으로 작용하지 않기 때문에 별도로 고려하지 않지만 노출암거의 경우에는 고려하고 있습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #268543 | Pile calculation report | 327 | 2026-09-28 |
| Answered | ACulvert | #268536 | Setting section changes in culvert | 166 | 2026-09-28 |
| Answered | ACulvert | #268524 | Design check not performed at wall center | 215 | 2026-09-27 |
| Answered | ACulvert | #268523 | Applying moving vehicle loads | 231 | 2026-09-27 |
| Answered | ACulvert | #268522 | Question about pile layout | 257 | 2026-09-23 |
| Answered | ACulvert | #268521 | Question about features | 128 | 2026-09-23 |
| Answered | ACulvert | #268510 | Question about joint check in Excel report output | 180 | 2026-09-22 |
| Answered | ACulvert | #268499 | Error in STM analysis of corner region | 139 | 2026-09-22 |
| Answered | ACulvert | #268471 | Launching the culvert program | 59 | 2026-09-18 |
| Answered | ACulvert | #268442 | All lines are displayed as dashed lines, what should I do? | 137 | 2026-09-17 |
| Answered | ACulvert | #268429 | Question about U-type underpass | 125 | 2026-09-17 |
| Answered | ACulvert | #268424 | Load position when applying railway loads to an underpass | 230 | 2026-09-17 |
| Answered | ACulvert | #268417 | Changing girder dimensions | 147 | 2026-09-17 |
| Answered | ACulvert | #268396 | Incorrect section check location for horizontal rebar | 173 | 2026-09-16 |
| Answered | ACulvert | #268376 | Question about segment settings for U-type retaining wall | 185 | 2026-09-15 |
| Answered | ACulvert | #268343 | Question about culvert drawing output | 126 | 2026-09-15 |
| Answered | ACulvert | #268337 | Inquiry about checking retaining-wall-type wing walls | 300 | 2026-09-14 |
| Answered | ACulvert | #268330 | About drawing output | 150 | 2026-09-14 |
| Answered | ACulvert | #268318 | Some blocks not displayed | 135 | 2026-09-14 |
| Answered | ACulvert | #268317 | Tank load for surcharge and moving loads | 334 | 2026-09-14 |