Question in Korean (English title coming soon)
첨부파일 지지력 검토에서 Qmax값이 256.101인데 243.461로 나옵니다.. 확인바랍니다..
Answer
안녕하세요. 한길아이티입니다. 상부 상재하중이 철도하중인 경우 지지력 검토에서 체크가 잘못된 오류가 있었습니다. 수정후 금일 패치에 적용토록 하겠습니다. 감사합니다.
Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #268543 | Pile calculation report | 327 | 2026-09-28 |
| Answered | ACulvert | #268536 | Setting section changes in culvert | 166 | 2026-09-28 |
| Answered | ACulvert | #268524 | Design check not performed at wall center | 215 | 2026-09-27 |
| Answered | ACulvert | #268523 | Applying moving vehicle loads | 231 | 2026-09-27 |
| Answered | ACulvert | #268522 | Question about pile layout | 259 | 2026-09-23 |
| Answered | ACulvert | #268521 | Question about features | 128 | 2026-09-23 |
| Answered | ACulvert | #268510 | Question about joint check in Excel report output | 180 | 2026-09-22 |
| Answered | ACulvert | #268499 | Error in STM analysis of corner region | 139 | 2026-09-22 |
| Answered | ACulvert | #268471 | Launching the culvert program | 59 | 2026-09-18 |
| Answered | ACulvert | #268442 | All lines are displayed as dashed lines, what should I do? | 137 | 2026-09-17 |
| Answered | ACulvert | #268429 | Question about U-type underpass | 126 | 2026-09-17 |
| Answered | ACulvert | #268424 | Load position when applying railway loads to an underpass | 230 | 2026-09-17 |
| Answered | ACulvert | #268417 | Changing girder dimensions | 147 | 2026-09-17 |
| Answered | ACulvert | #268396 | Incorrect section check location for horizontal rebar | 173 | 2026-09-16 |
| Answered | ACulvert | #268376 | Question about segment settings for U-type retaining wall | 185 | 2026-09-15 |
| Answered | ACulvert | #268343 | Question about culvert drawing output | 126 | 2026-09-15 |
| Answered | ACulvert | #268337 | Inquiry about checking retaining-wall-type wing walls | 300 | 2026-09-14 |
| Answered | ACulvert | #268330 | About drawing output | 150 | 2026-09-14 |
| Answered | ACulvert | #268318 | Some blocks not displayed | 135 | 2026-09-14 |
| Answered | ACulvert | #268317 | Tank load for surcharge and moving loads | 334 | 2026-09-14 |