Question in Korean (English title coming soon)

전화로 말씀드린 사항입니다. 이 파일만이 아니구 12/19이전에 작업한 다른 파일들도 체크해보니 모두 "지원되지 않는 작업을..." 이라는 에러문구가 나오면서 다운됩니다. 확인 부탁드립니다.

Answer

안녕하세요. 한길아이티입니다. 전화드리니 연락이 되지가 않네요 아마도 오늘 업데이트 중에 완전히 업데이트가 되지 않았던거 같습니다. 저희 쪽에서는 이상없이 작업이 진행되는데요 일단 업데이트를 다시 해보시길 바랍니다. AUpdate를 실행하시면 아마 Acuvlert가 체크가 되어 있지 않을것입니다. ACuvlert를 체크하시고 다시 업데이트를 받으시면 작업이 이상없이 진행될것입니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#268543Pile calculation report3272026-09-28
AnsweredACulvert#268536Setting section changes in culvert1662026-09-28
AnsweredACulvert#268524Design check not performed at wall center2152026-09-27
AnsweredACulvert#268523Applying moving vehicle loads2322026-09-27
AnsweredACulvert#268522Question about pile layout2602026-09-23
AnsweredACulvert#268521Question about features1282026-09-23
AnsweredACulvert#268510Question about joint check in Excel report output1802026-09-22
AnsweredACulvert#268499Error in STM analysis of corner region1392026-09-22
AnsweredACulvert#268471Launching the culvert program592026-09-18
AnsweredACulvert#268442All lines are displayed as dashed lines, what should I do?1382026-09-17
AnsweredACulvert#268429Question about U-type underpass1262026-09-17
AnsweredACulvert#268424Load position when applying railway loads to an underpass2302026-09-17
AnsweredACulvert#268417Changing girder dimensions1472026-09-17
AnsweredACulvert#268396Incorrect section check location for horizontal rebar1732026-09-16
AnsweredACulvert#268376Question about segment settings for U-type retaining wall1852026-09-15
AnsweredACulvert#268343Question about culvert drawing output1262026-09-15
AnsweredACulvert#268337Inquiry about checking retaining-wall-type wing walls3002026-09-14
AnsweredACulvert#268330About drawing output1502026-09-14
AnsweredACulvert#268318Some blocks not displayed1352026-09-14
AnsweredACulvert#268317Tank load for surcharge and moving loads3342026-09-14
Sign in to ask