AnsweredACulvertQ&A #2272792005-12-08 01:04 · Views 133

Coefficient of subgrade reaction

하루에 두번 질문을 올리네요 질문이 좀 깁니다. ----------------------------- 4. 지반반력계수 (지진시) 1) 지반탄성계수의 산정 ※ 성토재 (심도 : 3.200m ~ 0.000m) - Vo (초기상태 전단파 속도) = 80 × N^(1/3) = 80 × 30^(1/3) = 248.6 m/sec - Vs (붕괴방지수준의 전단파 속도) =0.8 × Vo = 0.8 × 248.6 = 124.3 m/sec - Gd (전단탄성계수) = w / g × Vs² ( w : 흙의 단위중량, g : 중력계수 ) = 20 / 9.806 × 124.3² = 31512.0 kN/m² - Ed (탄성계수) = 2 × ( 1 + ν ) × Gd ( ν : 흙의 포아슨 비 ) = 2 × ( 1 + 0.17 ) × 31512.0 = 88233.6 kN/m² ※ 실트섞인 자갈(GM) (심도 : 0.000m ~ -0.900m) - Vo (초기상태 전단파 속도) = 80 × N^(1/3) = 80 × 15^(1/3) = 197.3 m/sec - Vs (붕괴방지수준의 전단파 속도) =0.8 × Vo = 0.8 × 197.3 = 98.7 m/sec - Gd (전단탄성계수) = w / g × Vs² ( w : 흙의 단위중량, g : 중력계수 ) = 20 / 9.806 × 98.7² = 19869.0 kN/m² - Ed (탄성계수) = 2 × ( 1 + ν ) × Gd ( ν : 흙의 포아슨 비 ) = 2 × ( 1 + 0.4 ) × 19869.0 = 55633.2 kN/m² -------------------------------------------------------- 에서 1.※ 성토재와 실트섞인 자갈 의 심도 를 어떻게 책정하는지 알고싶습니다. 지반정보를 봐도 그 근거를 찾아내기가 힘드네요.. 지반정보에서 첫 토층이 0~-0.9m라서 제1토층을 그렇게 잡았는지.. 그렇다면 제0토층이 3.0m~0m인지. 그리고, 왜 제2토층과 제3토층은 없는지요.. 또한, 2."※ 성토재 (심도 : 3.200m ~ 0.000m) - Vo (초기상태 전단파 속도) = 80 × N^(1/3) = 80 × 30^(1/3) = 248.6 m/sec" 에서 N치가 지반정보의 N치인 15가 아닌 30을 대입시켰는데 근거를 모르겠습니다. 3.포와송의 비가 틀린것은 같은 흙이 여도 그 지질상태가 틀려서 달리 대입한지도 알고싶네요. 한 수 가르쳐 주십시요.. 수고하십쇼 ^^

Answer

안녕하세요. 한길아이티입니다. 전화상으로 말씀 드렸습니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#268543Pile calculation report3282026-09-28
AnsweredACulvert#268536Setting section changes in culvert1672026-09-28
AnsweredACulvert#268524Design check not performed at wall center2152026-09-27
AnsweredACulvert#268523Applying moving vehicle loads2322026-09-27
AnsweredACulvert#268522Question about pile layout2612026-09-23
AnsweredACulvert#268521Question about features1282026-09-23
AnsweredACulvert#268510Question about joint check in Excel report output1802026-09-22
AnsweredACulvert#268499Error in STM analysis of corner region1402026-09-22
AnsweredACulvert#268471Launching the culvert program592026-09-18
AnsweredACulvert#268442All lines are displayed as dashed lines, what should I do?1382026-09-17
AnsweredACulvert#268429Question about U-type underpass1262026-09-17
AnsweredACulvert#268424Load position when applying railway loads to an underpass2302026-09-17
AnsweredACulvert#268417Changing girder dimensions1472026-09-17
AnsweredACulvert#268396Incorrect section check location for horizontal rebar1742026-09-16
AnsweredACulvert#268376Question about segment settings for U-type retaining wall1852026-09-15
AnsweredACulvert#268343Question about culvert drawing output1262026-09-15
AnsweredACulvert#268337Inquiry about checking retaining-wall-type wing walls3002026-09-14
AnsweredACulvert#268330About drawing output1502026-09-14
AnsweredACulvert#268318Some blocks not displayed1362026-09-14
AnsweredACulvert#268317Tank load for surcharge and moving loads3342026-09-14
Sign in to ask