Question in Korean (English title coming soon)
2연암거 모델링이 단면설정과 조금 상이합니다. 사각을 고려한다고해도 이상합니다. 급하니 빠른 확인부탁드립니다. 또한 1연 암거도 확인해보니 차이가 몇cm 씩 차이가 나네요...TD 모델을 사용한것은 안그런데 TD를 사용하지 않은것은 모델링에서 오차가 발생합니다. 확인부탁드립니다.
Answer
안녕하세요. 한길아이티입니다. "설계환경 입력"메뉴, 설계선택사항 탭의 사각암거시 경사지간의 고려 옵션을 선택하면 적용되는 단면으로, 도로교 설계기준.해설 p.683페이지의 그림 4.8.2 - 경사슬래브교의 경간방향을 참조하여 산출된 단면크기 입니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #268543 | Pile calculation report | 328 | 2026-09-28 |
| Answered | ACulvert | #268536 | Setting section changes in culvert | 168 | 2026-09-28 |
| Answered | ACulvert | #268524 | Design check not performed at wall center | 215 | 2026-09-27 |
| Answered | ACulvert | #268523 | Applying moving vehicle loads | 233 | 2026-09-27 |
| Answered | ACulvert | #268522 | Question about pile layout | 261 | 2026-09-23 |
| Answered | ACulvert | #268521 | Question about features | 128 | 2026-09-23 |
| Answered | ACulvert | #268510 | Question about joint check in Excel report output | 181 | 2026-09-22 |
| Answered | ACulvert | #268499 | Error in STM analysis of corner region | 140 | 2026-09-22 |
| Answered | ACulvert | #268471 | Launching the culvert program | 59 | 2026-09-18 |
| Answered | ACulvert | #268442 | All lines are displayed as dashed lines, what should I do? | 138 | 2026-09-17 |
| Answered | ACulvert | #268429 | Question about U-type underpass | 126 | 2026-09-17 |
| Answered | ACulvert | #268424 | Load position when applying railway loads to an underpass | 230 | 2026-09-17 |
| Answered | ACulvert | #268417 | Changing girder dimensions | 147 | 2026-09-17 |
| Answered | ACulvert | #268396 | Incorrect section check location for horizontal rebar | 176 | 2026-09-16 |
| Answered | ACulvert | #268376 | Question about segment settings for U-type retaining wall | 185 | 2026-09-15 |
| Answered | ACulvert | #268343 | Question about culvert drawing output | 127 | 2026-09-15 |
| Answered | ACulvert | #268337 | Inquiry about checking retaining-wall-type wing walls | 301 | 2026-09-14 |
| Answered | ACulvert | #268330 | About drawing output | 151 | 2026-09-14 |
| Answered | ACulvert | #268318 | Some blocks not displayed | 136 | 2026-09-14 |
| Answered | ACulvert | #268317 | Tank load for surcharge and moving loads | 335 | 2026-09-14 |