AnsweredACulvertQ&A #2269472005-10-26 17:04 · Views 32

Under earthquake conditions

안녕하십니까. 조금전에 지진시에 대한 설명은 잘 들었습니다. 그런데, "- Vs (기능수행수준의 전단파 속도) = 0.5 × Vo = 0.5 × 197.3 = 98.7 m/sec " 에서 문구는 "기능수행수준"이면서 계수는 0.5로 들어가서 서로 이해차가 생긴문제인것 같습니다. 프로그램 설계환경을 바꾸어서 출력을 해보니, 기능수행수준과 붕괴방지수준 모두 각각의 계수는 맞게 들어가나, 문구가 모두 "기능수행수준"이라는 같은 문구로 들어갑니다. 붕괴방지는 붕괴방지로 출력될 수 있도록 해 주시면 보다 편히 프로그램을 쓸 수 있겠습니다.

Answer

안녕하세요. 한길아이티입니다. 각 성능 목표에 따른 텍스트를 수정하여 패치에 반영토록 하겠습니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#268543Pile calculation report3292026-09-28
AnsweredACulvert#268536Setting section changes in culvert1702026-09-28
AnsweredACulvert#268524Design check not performed at wall center2152026-09-27
AnsweredACulvert#268523Applying moving vehicle loads2342026-09-27
AnsweredACulvert#268522Question about pile layout2612026-09-23
AnsweredACulvert#268521Question about features1292026-09-23
AnsweredACulvert#268510Question about joint check in Excel report output1812026-09-22
AnsweredACulvert#268499Error in STM analysis of corner region1422026-09-22
AnsweredACulvert#268471Launching the culvert program592026-09-18
AnsweredACulvert#268442All lines are displayed as dashed lines, what should I do?1382026-09-17
AnsweredACulvert#268429Question about U-type underpass1262026-09-17
AnsweredACulvert#268424Load position when applying railway loads to an underpass2322026-09-17
AnsweredACulvert#268417Changing girder dimensions1472026-09-17
AnsweredACulvert#268396Incorrect section check location for horizontal rebar1772026-09-16
AnsweredACulvert#268376Question about segment settings for U-type retaining wall1882026-09-15
AnsweredACulvert#268343Question about culvert drawing output1272026-09-15
AnsweredACulvert#268337Inquiry about checking retaining-wall-type wing walls3012026-09-14
AnsweredACulvert#268330About drawing output1512026-09-14
AnsweredACulvert#268318Some blocks not displayed1362026-09-14
AnsweredACulvert#268317Tank load for surcharge and moving loads3352026-09-14
Sign in to ask