Correction to what I wrongly pointed out in post 2339
2. 본체 관련해서 2cycle 철근 수량의 오류를 지적했었는데, 제가 잘못 지적한 것입니다. 철근 수량은 맞게 산출됩니다. ^^;;; 좀더 잘 생각하고 글 올렸어야 했는데 죄송합니다... 수고하십시오. ---원문------------------------- 2. 본체 대부분 패치가 잘 적용되어 만족합니다. 그러나, 주철근 배치 입력시 소요 철근량이 작아서 2cycle에서 철근을 삭제할 경우, 1cycle의 철근량은 삭제전의 2cycle의 철근량을 합산한 양(개수)이 나옵니다. ---------------------------------
Answer
안녕하세요. 한길아이티입니다. 좋은 의견 감사합니다.참고토록 하겠습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #268543 | Pile calculation report | 329 | 2026-09-28 |
| Answered | ACulvert | #268536 | Setting section changes in culvert | 170 | 2026-09-28 |
| Answered | ACulvert | #268524 | Design check not performed at wall center | 215 | 2026-09-27 |
| Answered | ACulvert | #268523 | Applying moving vehicle loads | 234 | 2026-09-27 |
| Answered | ACulvert | #268522 | Question about pile layout | 261 | 2026-09-23 |
| Answered | ACulvert | #268521 | Question about features | 129 | 2026-09-23 |
| Answered | ACulvert | #268510 | Question about joint check in Excel report output | 181 | 2026-09-22 |
| Answered | ACulvert | #268499 | Error in STM analysis of corner region | 142 | 2026-09-22 |
| Answered | ACulvert | #268471 | Launching the culvert program | 59 | 2026-09-18 |
| Answered | ACulvert | #268442 | All lines are displayed as dashed lines, what should I do? | 138 | 2026-09-17 |
| Answered | ACulvert | #268429 | Question about U-type underpass | 126 | 2026-09-17 |
| Answered | ACulvert | #268424 | Load position when applying railway loads to an underpass | 232 | 2026-09-17 |
| Answered | ACulvert | #268417 | Changing girder dimensions | 147 | 2026-09-17 |
| Answered | ACulvert | #268396 | Incorrect section check location for horizontal rebar | 177 | 2026-09-16 |
| Answered | ACulvert | #268376 | Question about segment settings for U-type retaining wall | 188 | 2026-09-15 |
| Answered | ACulvert | #268343 | Question about culvert drawing output | 127 | 2026-09-15 |
| Answered | ACulvert | #268337 | Inquiry about checking retaining-wall-type wing walls | 301 | 2026-09-14 |
| Answered | ACulvert | #268330 | About drawing output | 151 | 2026-09-14 |
| Answered | ACulvert | #268318 | Some blocks not displayed | 136 | 2026-09-14 |
| Answered | ACulvert | #268317 | Tank load for surcharge and moving loads | 335 | 2026-09-14 |