수로암거에서 내부하중(내부수압)값을 넣어서 돌린 결과값과 넣지 않고 돌리 결과값(모멘트)값이 같습니다. 확인부탁드립니다.([개인정보]) 그리고 옹벽식 날개벽에서 철근배근을 하려고하면 에러메세지가 뜹니다. 이것도 확인해 주십시요.([개인정보], 파일명:[개인정보]) 그리고 하중조건에서 지점침하를 고려할 수 있는 옵션이나 방법이 있으면 알려 주셨으면 합니다.
Answer
안녕하세요. 한길아이티입니다. 1. 내부 수압적용 => 내부 수압적용시 오류가 있었습니다.수정후 패치에 적용토록 하겠습니다. 2. 옹벽 배근오류 => 수정하여 패치에 적용토록 하겠습니다. 3. 지점침하 => 지점침하 고려 관련 옵션은 지원하지 않고 있습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #268543 | Pile calculation report | 329 | 2026-09-28 |
| Answered | ACulvert | #268536 | Setting section changes in culvert | 170 | 2026-09-28 |
| Answered | ACulvert | #268524 | Design check not performed at wall center | 215 | 2026-09-27 |
| Answered | ACulvert | #268523 | Applying moving vehicle loads | 234 | 2026-09-27 |
| Answered | ACulvert | #268522 | Question about pile layout | 261 | 2026-09-23 |
| Answered | ACulvert | #268521 | Question about features | 129 | 2026-09-23 |
| Answered | ACulvert | #268510 | Question about joint check in Excel report output | 181 | 2026-09-22 |
| Answered | ACulvert | #268499 | Error in STM analysis of corner region | 142 | 2026-09-22 |
| Answered | ACulvert | #268471 | Launching the culvert program | 59 | 2026-09-18 |
| Answered | ACulvert | #268442 | All lines are displayed as dashed lines, what should I do? | 138 | 2026-09-17 |
| Answered | ACulvert | #268429 | Question about U-type underpass | 126 | 2026-09-17 |
| Answered | ACulvert | #268424 | Load position when applying railway loads to an underpass | 233 | 2026-09-17 |
| Answered | ACulvert | #268417 | Changing girder dimensions | 147 | 2026-09-17 |
| Answered | ACulvert | #268396 | Incorrect section check location for horizontal rebar | 177 | 2026-09-16 |
| Answered | ACulvert | #268376 | Question about segment settings for U-type retaining wall | 188 | 2026-09-15 |
| Answered | ACulvert | #268343 | Question about culvert drawing output | 128 | 2026-09-15 |
| Answered | ACulvert | #268337 | Inquiry about checking retaining-wall-type wing walls | 301 | 2026-09-14 |
| Answered | ACulvert | #268330 | About drawing output | 151 | 2026-09-14 |
| Answered | ACulvert | #268318 | Some blocks not displayed | 137 | 2026-09-14 |
| Answered | ACulvert | #268317 | Tank load for surcharge and moving loads | 335 | 2026-09-14 |