Minimum shear rebar check for walls

1. 콘크리트 설계기준 7.3.5항에 보면 최소전단 철근량이 나오는데요.. 여기에보면 Vu가 1/2Vc를 초과하는 모든 철근 콘크리트 휨부재는 다음의 경우를 제외하고 최소 전단 철근을 배치하게 되어있고, 그 예외 조항이 슬래브와 기초판 등등이 있습니다. 그러면 상부슬래브와 하부 슬래브는 1/2Vc를 고려하지 않아도 될 것 같은데, 이것을 슬래브에도 고려하면 전단철근이 과다하게 들어가는것 같습니다만.. 벽체에 대해서만 최소 전단 철근량 검토를 하게끔 해주셨으면 합니다. 2. 지반반력계수 kg/cm2 =>ton/m2으로 단위 변환하는데.. 변환 오류가 나오네요.. 예로 0.303kgf/cm2 => 3030 tonf/m2으로 바꿔야 되는데, 0이 하나 빠졌군요.. 확인 바랍니다.

Answer

안녕하세요. 한길아이티입니다. 1. [일반입력>설계환경입력>설계선택사항] 전단검토시 최소간격고려(벽체/슬래브)를 선택하시면 됩니다. 2. 1tonf/m2=1/10kgf/cm2 1tonf/m3=1/1000kgf/m3 입니다 다시한번 검토하시기 바랍니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#226813Horizontal alignment of 2-cell box is kinked482005-10-10
AnsweredACulvert#226812Retaining wall shear rebar482005-10-10
AnsweredACulvert#226809Calculation report won't output422005-10-09
AnsweredACulvert#226808Retaining wall reinforcement detailing382005-10-08
AnsweredACulvert#226805Uploading additional file302005-10-08
AnsweredACulvert#226802Entering skew at culvert start362005-10-08
AnsweredACulvert#226804Please review242005-10-07
AnsweredACulvert#226800Input problem with side ditch and haunch in 2-level 2-cell culvert602005-10-07
AnsweredACulvert#226797Structural calculation report output problem422005-10-07
AnsweredACulvert#226793Drawings not generated282005-10-07
AnsweredACulvert#226786Internal error occurs302005-10-06
AnsweredACulvert#226785Wing wall drawings not generated502005-10-06
AnsweredACulvert#226795Minimum shear rebar check for walls · Currently viewing692005-10-06
AnsweredACulvert#226783Please review542005-10-06
AnsweredACulvert#226782Please check752005-10-06
AnsweredACulvert#226791About culverts232005-10-06
AnsweredACulvert#226789Approach slab shear rebar502005-10-06
AnsweredACulvert#226780About retaining-wall-type wing walls432005-10-06
AnsweredACulvert#226778About concrete elastic modulus652005-10-05
AnsweredACulvert#226775Design check for pile foundations502005-10-05
Sign in to ask