Modeling

기초자료에서부터 "다음" 버튼을 눌러 쭉 가면 모델링이 찌그러집니다. 그렇게 하지않고, 중간단계를 뛰어넘어서 모델링 단계로 가면 모델링이 제대로 나오고요.. 모델링이 찌그러진 것과 같이 올립니다. 검토바랍니다.

Answer

안녕하세요. 한길아이티입니다. 어제 저녁 6시 패치시 설계환경 입력의 설계선택 사항 텝에 보시면 밑에서 데이터 3개가 저장 오류가 있었습니다. 하부 스프링기준간격,내진계산시 벽체 스프링기준간격,노출암거 수평토압 산정시 상재활하중 등 위 3개 데이터 저장 오류로 인하여 모델링시 오류가 있었습니다. 패치를 어제 저녁 20시30분에 다시 올렸으니 패치를 다시 받으신후 설계선택 사항의 위 3개 데이터를 확인해주시면 됩니다. 불편을 드려 죄송합니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#268543Pile calculation report3292026-09-28
AnsweredACulvert#268536Setting section changes in culvert1712026-09-28
AnsweredACulvert#268524Design check not performed at wall center2152026-09-27
AnsweredACulvert#268523Applying moving vehicle loads2352026-09-27
AnsweredACulvert#268522Question about pile layout2612026-09-23
AnsweredACulvert#268521Question about features1292026-09-23
AnsweredACulvert#268510Question about joint check in Excel report output1842026-09-22
AnsweredACulvert#268499Error in STM analysis of corner region1422026-09-22
AnsweredACulvert#268471Launching the culvert program592026-09-18
AnsweredACulvert#268442All lines are displayed as dashed lines, what should I do?1392026-09-17
AnsweredACulvert#268429Question about U-type underpass1262026-09-17
AnsweredACulvert#268424Load position when applying railway loads to an underpass2342026-09-17
AnsweredACulvert#268417Changing girder dimensions1502026-09-17
AnsweredACulvert#268396Incorrect section check location for horizontal rebar1782026-09-16
AnsweredACulvert#268376Question about segment settings for U-type retaining wall1892026-09-15
AnsweredACulvert#268343Question about culvert drawing output1282026-09-15
AnsweredACulvert#268337Inquiry about checking retaining-wall-type wing walls3032026-09-14
AnsweredACulvert#268330About drawing output1512026-09-14
AnsweredACulvert#268318Some blocks not displayed1382026-09-14
AnsweredACulvert#268317Tank load for surcharge and moving loads3352026-09-14
Sign in to ask