Skip to content
AnsweredACulvertQ&A #2266262005-09-14 22:59 · Views 32

Load calculation error

5) 토 압 (지하수가 없을경우) - Wh2 = 7.317 + 0.300 × 20.000 × 0.426 = 9.877kN/m² 6) 토 압 (지하수가 있을경우) - Wh2 = 7.320 + 0.300 × 20.000 × 0.426 = 0.988kN/m² =====================>>> 제가 현재 확인한 것은 이 두가지 입니다.

Answer

안녕하세요. 한길아이티입니다. 오류사항을 확인하였습니다. 수정하여 패치에 반영하겠습니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#268543Pile calculation report3292026-09-28
AnsweredACulvert#268536Setting section changes in culvert1712026-09-28
AnsweredACulvert#268524Design check not performed at wall center2152026-09-27
AnsweredACulvert#268523Applying moving vehicle loads2352026-09-27
AnsweredACulvert#268522Question about pile layout2612026-09-23
AnsweredACulvert#268521Question about features1302026-09-23
AnsweredACulvert#268510Question about joint check in Excel report output1842026-09-22
AnsweredACulvert#268499Error in STM analysis of corner region1422026-09-22
AnsweredACulvert#268471Launching the culvert program592026-09-18
AnsweredACulvert#268442All lines are displayed as dashed lines, what should I do?1392026-09-17
AnsweredACulvert#268429Question about U-type underpass1262026-09-17
AnsweredACulvert#268424Load position when applying railway loads to an underpass2352026-09-17
AnsweredACulvert#268417Changing girder dimensions1522026-09-17
AnsweredACulvert#268396Incorrect section check location for horizontal rebar1802026-09-16
AnsweredACulvert#268376Question about segment settings for U-type retaining wall1902026-09-15
AnsweredACulvert#268343Question about culvert drawing output1282026-09-15
AnsweredACulvert#268337Inquiry about checking retaining-wall-type wing walls3042026-09-14
AnsweredACulvert#268330About drawing output1522026-09-14
AnsweredACulvert#268318Some blocks not displayed1382026-09-14
AnsweredACulvert#268317Tank load for surcharge and moving loads3372026-09-14
Sign in to ask