Skip to content
AnsweredACulvertQ&A #2264722005-08-23 19:27 · Views 28

Please check main rebar assembly drawing

주철근 배치 입력에서 상,하부 슬래브 및 벽체의 내측철근이 우각부 외측 주철근의 라운드 부분을 벗어나서 표현되고있습니다. 검토 부탁드립니다

Answer

안녕하세요. 한길아이티입니다. 내측 철근을 주철근에 맞추다보니 라운드 부분에서 튀어나온 오류가 있었습니다. 수정하여 패치에 반영토록 하겠습니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#268543Pile calculation report3292026-09-28
AnsweredACulvert#268536Setting section changes in culvert1732026-09-28
AnsweredACulvert#268524Design check not performed at wall center2162026-09-27
AnsweredACulvert#268523Applying moving vehicle loads2362026-09-27
AnsweredACulvert#268522Question about pile layout2612026-09-23
AnsweredACulvert#268521Question about features1302026-09-23
AnsweredACulvert#268510Question about joint check in Excel report output1842026-09-22
AnsweredACulvert#268499Error in STM analysis of corner region1432026-09-22
AnsweredACulvert#268471Launching the culvert program592026-09-18
AnsweredACulvert#268442All lines are displayed as dashed lines, what should I do?1392026-09-17
AnsweredACulvert#268429Question about U-type underpass1262026-09-17
AnsweredACulvert#268424Load position when applying railway loads to an underpass2362026-09-17
AnsweredACulvert#268417Changing girder dimensions1522026-09-17
AnsweredACulvert#268396Incorrect section check location for horizontal rebar1822026-09-16
AnsweredACulvert#268376Question about segment settings for U-type retaining wall1912026-09-15
AnsweredACulvert#268343Question about culvert drawing output1282026-09-15
AnsweredACulvert#268337Inquiry about checking retaining-wall-type wing walls3052026-09-14
AnsweredACulvert#268330About drawing output1532026-09-14
AnsweredACulvert#268318Some blocks not displayed1392026-09-14
AnsweredACulvert#268317Tank load for surcharge and moving loads3382026-09-14
Sign in to ask