Skip to content
AnsweredACulvertQ&A #2263422005-07-22 15:11 · Views 40

Bracket

브래킷을 설계할때 브래킷끝부분에 BR1철근과 BR2철근사이로 배력철근을 상하로 배치하고싶은데 선택옵션이 없는것 같습니다. 예제도면을 같이 첨부해 드립니다. 확인후 답변바라겠습니다. 수고하십시요.

Answer

안녕하세요. 한길아이티입니다. [개인정보] 담당자가 휴가를 떠난 관계로 25일 ~ 26일 사이에 추가하여 패치에 반영토록 하겠습니다. 또한 접속슬래브 배력근 검토 관련하여 현재 콘크리트 설계기준인 경우에만 추가 되었습니다.도로 설계기준일때에도 추가하여 브라켓 [개인정보]도와 같은 날짜에 업그레이드 하도록 하겠습니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#268543Pile calculation report3292026-09-28
AnsweredACulvert#268536Setting section changes in culvert1732026-09-28
AnsweredACulvert#268524Design check not performed at wall center2162026-09-27
AnsweredACulvert#268523Applying moving vehicle loads2372026-09-27
AnsweredACulvert#268522Question about pile layout2612026-09-23
AnsweredACulvert#268521Question about features1302026-09-23
AnsweredACulvert#268510Question about joint check in Excel report output1842026-09-22
AnsweredACulvert#268499Error in STM analysis of corner region1432026-09-22
AnsweredACulvert#268471Launching the culvert program592026-09-18
AnsweredACulvert#268442All lines are displayed as dashed lines, what should I do?1392026-09-17
AnsweredACulvert#268429Question about U-type underpass1262026-09-17
AnsweredACulvert#268424Load position when applying railway loads to an underpass2372026-09-17
AnsweredACulvert#268417Changing girder dimensions1522026-09-17
AnsweredACulvert#268396Incorrect section check location for horizontal rebar1832026-09-16
AnsweredACulvert#268376Question about segment settings for U-type retaining wall1912026-09-15
AnsweredACulvert#268343Question about culvert drawing output1282026-09-15
AnsweredACulvert#268337Inquiry about checking retaining-wall-type wing walls3062026-09-14
AnsweredACulvert#268330About drawing output1532026-09-14
AnsweredACulvert#268318Some blocks not displayed1392026-09-14
AnsweredACulvert#268317Tank load for surcharge and moving loads3382026-09-14
Sign in to ask