하부슬래브 1경간 중앙부에서 주철근 배치입력에서 입력된 철근과 구조계산서에서 출력된 철근이 서로 다르게 나옵니다. 또한 갯수도 이상합니다. 확인부탁드립니다.
Answer
안녕하세요. 한길아이티입니다. 1경간 하부슬래브 중앙부에 부모멘트가 발생하여 하면철근을 가져와서 사용한 경우입니다. 부재력 및 극한하중 모멘트도를 확인해 보시길 바랍니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #268543 | Pile calculation report | 329 | 2026-09-28 |
| Answered | ACulvert | #268536 | Setting section changes in culvert | 173 | 2026-09-28 |
| Answered | ACulvert | #268524 | Design check not performed at wall center | 216 | 2026-09-27 |
| Answered | ACulvert | #268523 | Applying moving vehicle loads | 237 | 2026-09-27 |
| Answered | ACulvert | #268522 | Question about pile layout | 261 | 2026-09-23 |
| Answered | ACulvert | #268521 | Question about features | 130 | 2026-09-23 |
| Answered | ACulvert | #268510 | Question about joint check in Excel report output | 184 | 2026-09-22 |
| Answered | ACulvert | #268499 | Error in STM analysis of corner region | 143 | 2026-09-22 |
| Answered | ACulvert | #268471 | Launching the culvert program | 59 | 2026-09-18 |
| Answered | ACulvert | #268442 | All lines are displayed as dashed lines, what should I do? | 139 | 2026-09-17 |
| Answered | ACulvert | #268429 | Question about U-type underpass | 126 | 2026-09-17 |
| Answered | ACulvert | #268424 | Load position when applying railway loads to an underpass | 237 | 2026-09-17 |
| Answered | ACulvert | #268417 | Changing girder dimensions | 152 | 2026-09-17 |
| Answered | ACulvert | #268396 | Incorrect section check location for horizontal rebar | 183 | 2026-09-16 |
| Answered | ACulvert | #268376 | Question about segment settings for U-type retaining wall | 191 | 2026-09-15 |
| Answered | ACulvert | #268343 | Question about culvert drawing output | 128 | 2026-09-15 |
| Answered | ACulvert | #268337 | Inquiry about checking retaining-wall-type wing walls | 306 | 2026-09-14 |
| Answered | ACulvert | #268330 | About drawing output | 153 | 2026-09-14 |
| Answered | ACulvert | #268318 | Some blocks not displayed | 139 | 2026-09-14 |
| Answered | ACulvert | #268317 | Tank load for surcharge and moving loads | 338 | 2026-09-14 |