Rebar arrangement at cutoff points
단절점부 철근배치시 위치가 주철근 밖으로 밀려서 배치됩니다. 참고로 도로교 설계기준에서는 0.4R~0.65R사이에 배치(도로교설계기준해설-2003(718p.~720p.)되어야합니다. 임의대로 위치설정을 할수있는 방법은 없는지.. 검토하시고 연락 기다리겠습니다. [개인정보]
Answer
안녕하세요. 한길아이티입니다. 단절점부 보강철근 기준인 0.4로 배치한 경우입니다.입력한 단면에서 하부 슬래브두께(400), 벽체두께(300), 피복(100)으로 배근되어 주철근 밖으로 나간경우 입니다. 해석상 단절점 보강이 필요하므로 피복두께를 조정하셔야 될듯합니다. 0.4R은 말씀하신거와 같이 정해진 값이라서 프로그램내에서는 임의 수정을 지원하지 않고 있습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #226325 | File attached | 35 | 2005-07-16 |
| Answered | ACulvert | #226323 | Lap splices in the 2nd cycle | 38 | 2005-07-16 |
| Answered | ACulvert | #226324 | File won't open | 38 | 2005-07-15 |
| Answered | ACulvert | #226321 | Shear rebar spacing error | 59 | 2005-07-14 |
| Answered | ACulvert | #226319 | Culvert cross-section configuration field not enabled | 50 | 2005-07-13 |
| Answered | ACulvert | #226317 | Rebar arrangement at cutoff points · Currently viewing | 49 | 2005-07-13 |
| Answered | ACulvert | #226315 | About upgrade | 36 | 2005-07-13 |
| Answered | ACulvert | #226313 | About rebar spacing | 41 | 2005-07-12 |
| Answered | ACulvert | #226311 | Distribution rebar arrangement | 47 | 2005-07-12 |
| Answered | ACulvert | #226309 | Check at mid-height of culvert wall | 41 | 2005-07-11 |
| Answered | ACulvert | #226305 | About distribution rebar check | 47 | 2005-07-11 |
| Answered | ACulvert | #226306 | About additional loads | 54 | 2005-07-11 |
| Answered | ACulvert | #226303 | Cannot change bottom main rebar in U-type open channel | 42 | 2005-07-08 |
| Answered | ACulvert | #226301 | Modeling error | 29 | 2005-07-06 |
| Answered | ACulvert | #226297 | Question about U-type wall | 36 | 2005-07-05 |
| Answered | ACulvert | #226299 | Section where superelevation equals slope | 52 | 2005-07-05 |
| Answered | ACulvert | #226294 | Please check SI-CGS units | 39 | 2005-07-04 |
| Answered | ACulvert | #226293 | Seismic analysis and corner check | 89 | 2005-07-04 |
| Answered | ACulvert | #226291 | Unclear rebar arrangement in U-type open channel | 50 | 2005-07-02 |
| Answered | ACulvert | #226287 | File with eccentric live load placement | 43 | 2005-06-29 |