Skip to content
AnsweredACulvertQ&A #2262672005-06-24 09:30 · Views 58

Please check distribution rebar quantity

바쁜데 귀찬게 해드려 죄송합니다.

Answer

안녕하세요. 한길아이티입니다. 도로교 일때 -> 토피1m이하의 노출라멘(활하중직접제하) 주철근이 차량진행방향에 직각일때 120/sqrt(L)과 67% 중 작은값, 주철근이 차량진행방향에 평행할때 55 /sqrt(L)과 50% 중 작은값을 사용 ( 도로교 설계기준해설.2003 p231) 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#268543Pile calculation report3292026-09-28
AnsweredACulvert#268536Setting section changes in culvert1742026-09-28
AnsweredACulvert#268524Design check not performed at wall center2162026-09-27
AnsweredACulvert#268523Applying moving vehicle loads2382026-09-27
AnsweredACulvert#268522Question about pile layout2612026-09-23
AnsweredACulvert#268521Question about features1302026-09-23
AnsweredACulvert#268510Question about joint check in Excel report output1842026-09-22
AnsweredACulvert#268499Error in STM analysis of corner region1442026-09-22
AnsweredACulvert#268471Launching the culvert program592026-09-18
AnsweredACulvert#268442All lines are displayed as dashed lines, what should I do?1402026-09-17
AnsweredACulvert#268429Question about U-type underpass1262026-09-17
AnsweredACulvert#268424Load position when applying railway loads to an underpass2372026-09-17
AnsweredACulvert#268417Changing girder dimensions1522026-09-17
AnsweredACulvert#268396Incorrect section check location for horizontal rebar1832026-09-16
AnsweredACulvert#268376Question about segment settings for U-type retaining wall1922026-09-15
AnsweredACulvert#268343Question about culvert drawing output1282026-09-15
AnsweredACulvert#268337Inquiry about checking retaining-wall-type wing walls3062026-09-14
AnsweredACulvert#268330About drawing output1532026-09-14
AnsweredACulvert#268318Some blocks not displayed1402026-09-14
AnsweredACulvert#268317Tank load for surcharge and moving loads3392026-09-14
Sign in to ask
Please check distribution rebar quantity · aroad