Inquiry about bearing capacity check
최대지반반력에 대해 전화로 문의 드렸던 사항입니다. 자료를 첨부하겠습니다. 확인부탁드립니다.
Answer
안녕하세요. 한길아이티입니다. 최대 지반반력 산출시 도로노면활하중,암거내부 활하중의 데이터가 SI 변경시 잘못 되었습니다. 허용 지지력 검토시의 지반반력 값은 옳바르게 적용되어 있습니다. 수정하여 금일 패치에 적용토록 하겠습니다. 감사합니다.
Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #268543 | Pile calculation report | 329 | 2026-09-28 |
| Answered | ACulvert | #268536 | Setting section changes in culvert | 174 | 2026-09-28 |
| Answered | ACulvert | #268524 | Design check not performed at wall center | 217 | 2026-09-27 |
| Answered | ACulvert | #268523 | Applying moving vehicle loads | 238 | 2026-09-27 |
| Answered | ACulvert | #268522 | Question about pile layout | 262 | 2026-09-23 |
| Answered | ACulvert | #268521 | Question about features | 130 | 2026-09-23 |
| Answered | ACulvert | #268510 | Question about joint check in Excel report output | 185 | 2026-09-22 |
| Answered | ACulvert | #268499 | Error in STM analysis of corner region | 144 | 2026-09-22 |
| Answered | ACulvert | #268471 | Launching the culvert program | 59 | 2026-09-18 |
| Answered | ACulvert | #268442 | All lines are displayed as dashed lines, what should I do? | 140 | 2026-09-17 |
| Answered | ACulvert | #268429 | Question about U-type underpass | 126 | 2026-09-17 |
| Answered | ACulvert | #268424 | Load position when applying railway loads to an underpass | 237 | 2026-09-17 |
| Answered | ACulvert | #268417 | Changing girder dimensions | 152 | 2026-09-17 |
| Answered | ACulvert | #268396 | Incorrect section check location for horizontal rebar | 184 | 2026-09-16 |
| Answered | ACulvert | #268376 | Question about segment settings for U-type retaining wall | 193 | 2026-09-15 |
| Answered | ACulvert | #268343 | Question about culvert drawing output | 128 | 2026-09-15 |
| Answered | ACulvert | #268337 | Inquiry about checking retaining-wall-type wing walls | 306 | 2026-09-14 |
| Answered | ACulvert | #268330 | About drawing output | 154 | 2026-09-14 |
| Answered | ACulvert | #268318 | Some blocks not displayed | 141 | 2026-09-14 |
| Answered | ACulvert | #268317 | Tank load for surcharge and moving loads | 341 | 2026-09-14 |