Skip to content
AnsweredACulvertQ&A #2257262005-01-07 22:50 · Views 100

Serviceability check

벽체 중앙부 사용성 검토시 모멘트 값이 단면력정리에서 나온 사용하중의 값가 상이하네요... 확인 부탁드립니다......

Answer

안녕하세요. 한길아이티입니다. 옵션에 따른 검토결과 사용성검토시의 모멘트는 맞게 적용되었고, 철근검토에 사용된 모멘트값이 잘 못 적용 되었습니다. 수정후 패치에 반영하겠습니다. 감사합니다.