Serviceability check
벽체 중앙부 사용성 검토시 모멘트 값이 단면력정리에서 나온 사용하중의 값가 상이하네요... 확인 부탁드립니다......
Answer
안녕하세요. 한길아이티입니다. 옵션에 따른 검토결과 사용성검토시의 모멘트는 맞게 적용되었고, 철근검토에 사용된 모멘트값이 잘 못 적용 되었습니다. 수정후 패치에 반영하겠습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #268543 | Pile calculation report | 329 | 2026-09-28 |
| Answered | ACulvert | #268536 | Setting section changes in culvert | 174 | 2026-09-28 |
| Answered | ACulvert | #268524 | Design check not performed at wall center | 217 | 2026-09-27 |
| Answered | ACulvert | #268523 | Applying moving vehicle loads | 239 | 2026-09-27 |
| Answered | ACulvert | #268522 | Question about pile layout | 262 | 2026-09-23 |
| Answered | ACulvert | #268521 | Question about features | 130 | 2026-09-23 |
| Answered | ACulvert | #268510 | Question about joint check in Excel report output | 185 | 2026-09-22 |
| Answered | ACulvert | #268499 | Error in STM analysis of corner region | 144 | 2026-09-22 |
| Answered | ACulvert | #268471 | Launching the culvert program | 59 | 2026-09-18 |
| Answered | ACulvert | #268442 | All lines are displayed as dashed lines, what should I do? | 140 | 2026-09-17 |
| Answered | ACulvert | #268429 | Question about U-type underpass | 126 | 2026-09-17 |
| Answered | ACulvert | #268424 | Load position when applying railway loads to an underpass | 237 | 2026-09-17 |
| Answered | ACulvert | #268417 | Changing girder dimensions | 152 | 2026-09-17 |
| Answered | ACulvert | #268396 | Incorrect section check location for horizontal rebar | 184 | 2026-09-16 |
| Answered | ACulvert | #268376 | Question about segment settings for U-type retaining wall | 194 | 2026-09-15 |
| Answered | ACulvert | #268343 | Question about culvert drawing output | 129 | 2026-09-15 |
| Answered | ACulvert | #268337 | Inquiry about checking retaining-wall-type wing walls | 306 | 2026-09-14 |
| Answered | ACulvert | #268330 | About drawing output | 154 | 2026-09-14 |
| Answered | ACulvert | #268318 | Some blocks not displayed | 141 | 2026-09-14 |
| Answered | ACulvert | #268317 | Tank load for surcharge and moving loads | 342 | 2026-09-14 |