Question about Aline
안녕하세요 Aline 선형계산에서 완화곡선이 안들어 가야 하는데 들어가네요.. 철도선형이구요 파알 첨부합니다. 답변 부탁드립니다.
Answer
안녕하세요. 한길아이티입니다. 기준 선형인 이 완화곡선(3차포물선)으로 입력되어 있습니다. 완화 곡선이 아닌경우 값을 "0" 처리하시면 됩니다. . 입력 오류 사항 - 3번째 선형 입력 데이터에 좌표값이 모두 "0"로 입력되어 있습니다. 해당 선형을 로 삭제 또는 데이터 값을 올바르게 입력 바랍니다. 감사합니다.
Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #225733 | About rebar splice options | 119 | 2005-01-12 |
| Answered | ACulvert | #225735 | Section check and illustration errors | 124 | 2005-01-12 |
| Answered | ACulvert | #225731 | Internal application error message appears | 110 | 2005-01-11 |
| Answered | ACulvert | #225729 | About temperature load | 120 | 2005-01-10 |
| Answered | ACulvert | #225726 | Serviceability check | 100 | 2005-01-07 |
| Answered | ACulvert | #225725 | Uploading file | 83 | 2005-01-07 |
| Answered | ACulvert | #225723 | Six-cell culvert | 89 | 2005-01-06 |
| Answered | ACulvert | #225720 | Question about Aline · Currently viewing | 96 | 2005-01-06 |
| Answered | ACulvert | #225719 | Beams and columns | 51 | 2005-01-06 |
| Answered | ACulvert | #225717 | Please recheck retaining wall rebar numbers | 58 | 2005-01-06 |
| Answered | ACulvert | #225709 | Rebar numbers in retaining wall look wrong | 57 | 2005-01-05 |
| Answered | ACulvert | #225714 | About the calculation report | 60 | 2005-01-05 |
| Answered | ACulvert | #225713 | About drawing generation | 48 | 2005-01-05 |
| Answered | ACulvert | #225710 | Problem with seismic modeling | 41 | 2005-01-05 |
| Answered | ACulvert | #225706 | Attempted to access an unnamed file past its end | 145 | 2005-01-05 |
| Answered | ACulvert | #225704 | Inquiry | 82 | 2005-01-05 |
| Answered | ACulvert | #225703 | About the retaining wall reinforcement drawing... | 55 | 2005-01-05 |
| Answered | ACulvert | #225701 | Warning message | 52 | 2005-01-05 |
| Answered | ACulvert | #225699 | Question about culvert reinforcement drawing | 44 | 2005-01-04 |
| Answered | ACulvert | #225697 | Distribution rebar and approach slab calculation error | 59 | 2004-12-30 |