Skip to content
AnsweredACulvertQ&A #2255752004-12-01 06:38 · Views 43

Thickness input for parallel wing wall

평행식 날개벽 제원 입력중에서.. 두께(T2) 입력부분이 입력할 수 없는 상태로 되어있습니다. 검토 부탁드립니다.

Answer

안녕하세요. 한길아이티입니다. 일체식 날개벽에는 현재 도로공사 타입과 건교부 타입을 지원하고 있습니다. 2가지 타입은 난간벽의 유무와 관련이 있습니다. 1. 도로공사 타입 : 암거 벽체쪽 날개벽의 두께는 난간벽의 두께와 동일하게 설정이 됩니다. 도공 타입은 벽체쪽 두께는 난간벽과 일치하기 때문에 변경이 안됩니다. 2. 건교부 타입 : 건교부 타입은 날개벽의 두께가 일정한 형태로 유지 됩니다.날개벽 외측 두께를 변경하시면 암거 벽체쪽 날개벽 두께가 외측과 동일하게 변경이 됩니다. 외측과 벽체쪽 날개벽 두께를 임의로 조정이 가능합니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#268543Pile calculation report3292026-09-28
AnsweredACulvert#268536Setting section changes in culvert1742026-09-28
AnsweredACulvert#268524Design check not performed at wall center2172026-09-27
AnsweredACulvert#268523Applying moving vehicle loads2392026-09-27
AnsweredACulvert#268522Question about pile layout2622026-09-23
AnsweredACulvert#268521Question about features1302026-09-23
AnsweredACulvert#268510Question about joint check in Excel report output1852026-09-22
AnsweredACulvert#268499Error in STM analysis of corner region1442026-09-22
AnsweredACulvert#268471Launching the culvert program592026-09-18
AnsweredACulvert#268442All lines are displayed as dashed lines, what should I do?1402026-09-17
AnsweredACulvert#268429Question about U-type underpass1262026-09-17
AnsweredACulvert#268424Load position when applying railway loads to an underpass2372026-09-17
AnsweredACulvert#268417Changing girder dimensions1522026-09-17
AnsweredACulvert#268396Incorrect section check location for horizontal rebar1842026-09-16
AnsweredACulvert#268376Question about segment settings for U-type retaining wall1942026-09-15
AnsweredACulvert#268343Question about culvert drawing output1292026-09-15
AnsweredACulvert#268337Inquiry about checking retaining-wall-type wing walls3062026-09-14
AnsweredACulvert#268330About drawing output1542026-09-14
AnsweredACulvert#268318Some blocks not displayed1412026-09-14
AnsweredACulvert#268317Tank load for surcharge and moving loads3422026-09-14