During section check
수고가 많으십니다 단면검토시 상하부단면은 800mm 이고, 상부슬래브 헌치는 2000x500이고 하부슬래브 헌치는 1500x500 입니다. 상부슬래브 단부 단면검토시 H = 800+500 = 1300mm이고 하부슬래브 단부 단면검토시 H = 800+500 = 1300mm가 되어야 할것같은데 계산서를 출력해보니 상부슬래브 단부 H = 1466.67mm로 되어있어서 오류가 발생된것같아서 문의 드립니다. 확인해보시고 답변부탁드립니다~ 수고하세요~
Answer
안녕하세요. 한길아이티입니다. 확인해 본 결과 이상 없습니다. 도로교설계기준(건교부, 2000) p378 과 도로설계편람 Ⅲ권(건교부,2001) 507-78, 507-107 의 내용을 보시기 바랍니다. 산식은 상부슬래브 단부 단면검토시 H = 800+2000/3 = 1466.67mm이고 하부슬래브 단부 단면검토시 H = 800+1500/3= 1300mm가 맞습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #225514 | Dead load calculation | 72 | 2004-11-15 |
| Answered | ACulvert | #225511 | Please review | 50 | 2004-11-14 |
| Answered | ACulvert | #225510 | During section check · Currently viewing | 52 | 2004-11-13 |
| Answered | ACulvert | #225505 | About passage culvert | 70 | 2004-11-12 |
| Answered | ACulvert | #225504 | Question | 37 | 2004-11-12 |
| Answered | ACulvert | #225502 | Live load | 62 | 2004-11-12 |
| Answered | ACulvert | #225500 | Modeling error | 44 | 2004-11-12 |
| Answered | ACulvert | #225501 | Pile check | 45 | 2004-11-12 |
| Answered | ACulvert | #225496 | About culvert alignment | 45 | 2004-11-11 |
| Answered | ACulvert | #225498 | Checking U-type open channel results | 41 | 2004-11-11 |
| Answered | ACulvert | #225492 | Question about pavement inside water culvert | 56 | 2004-11-10 |
| Answered | ACulvert | #225489 | Error when opening file | 46 | 2004-11-10 |
| Answered | ACulvert | #225494 | About cover and rebar spacing | 56 | 2004-11-10 |
| Answered | ACulvert | #225487 | Retaining wall quantity check | 50 | 2004-11-10 |
| Answered | ACulvert | #225479 | Delay in generating quantity file | 53 | 2004-11-09 |
| Answered | ACulvert | #225485 | Question about wall rebar amount | 64 | 2004-11-09 |
| Answered | ACulvert | #225483 | Question about ground input | 47 | 2004-11-09 |
| Answered | ACulvert | #225481 | Question about section input | 49 | 2004-11-09 |
| Answered | ACulvert | #225477 | Retaining wall section check issue | 53 | 2004-11-09 |
| Answered | ACulvert | #225475 | About U-type and passage culvert | 76 | 2004-11-08 |