Please check this
허용균열폭이 넘 작게 나오네요!!! 급해요...^^
Answer
안녕하세요. 한길아이티입니다. 검토한 결과 이상없습니다. 상하부 중앙부의 철근덮개를 4.5cm로 입력하셨기 때문에 작게 나왔습니다. 허용균열폭 Wa = 0.005tc (습윤 환경) = 0.0050 x (45.00 - 29/2) = 0.153 mm 또한 전화상으로 문의하신 φMn 값도 검토결과 이상이 없습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #268543 | Pile calculation report | 329 | 2026-09-28 |
| Answered | ACulvert | #268536 | Setting section changes in culvert | 174 | 2026-09-28 |
| Answered | ACulvert | #268524 | Design check not performed at wall center | 217 | 2026-09-27 |
| Answered | ACulvert | #268523 | Applying moving vehicle loads | 239 | 2026-09-27 |
| Answered | ACulvert | #268522 | Question about pile layout | 263 | 2026-09-23 |
| Answered | ACulvert | #268521 | Question about features | 130 | 2026-09-23 |
| Answered | ACulvert | #268510 | Question about joint check in Excel report output | 185 | 2026-09-22 |
| Answered | ACulvert | #268499 | Error in STM analysis of corner region | 144 | 2026-09-22 |
| Answered | ACulvert | #268471 | Launching the culvert program | 59 | 2026-09-18 |
| Answered | ACulvert | #268442 | All lines are displayed as dashed lines, what should I do? | 140 | 2026-09-17 |
| Answered | ACulvert | #268429 | Question about U-type underpass | 126 | 2026-09-17 |
| Answered | ACulvert | #268424 | Load position when applying railway loads to an underpass | 237 | 2026-09-17 |
| Answered | ACulvert | #268417 | Changing girder dimensions | 152 | 2026-09-17 |
| Answered | ACulvert | #268396 | Incorrect section check location for horizontal rebar | 184 | 2026-09-16 |
| Answered | ACulvert | #268376 | Question about segment settings for U-type retaining wall | 194 | 2026-09-15 |
| Answered | ACulvert | #268343 | Question about culvert drawing output | 129 | 2026-09-15 |
| Answered | ACulvert | #268337 | Inquiry about checking retaining-wall-type wing walls | 306 | 2026-09-14 |
| Answered | ACulvert | #268330 | About drawing output | 154 | 2026-09-14 |
| Answered | ACulvert | #268318 | Some blocks not displayed | 141 | 2026-09-14 |
| Answered | ACulvert | #268317 | Tank load for surcharge and moving loads | 342 | 2026-09-14 |