Skip to content
AnsweredAAbutPierQ&A #2058092007-08-16 14:32 · Views 39

Earth pressure calculation error in MASS foundation stability check

MASS 기초 사용시 기초 안정검토 전단검토 - 교대저판 기준으로 검토 - 프로그램상에서 제대로 구현됨 활동검토 - 토압산정시 MASS 기초 하단면까지 산정되어야 하나 교대저판까지만 산정 교대구체에 대한 작용점 위치가 틀려지므로 잘못 계산되어짐 - 수정요구 지지력검토 - MASS기초 반력이 포함되어 있음 - 프로그램상에서 제대로 구현됨. 결론 활동검토가 잘못 되어있으므로 토압산정과 작용점 위치를 MASS 기초를 포함해서 산정해주시기 바랍니다.

Answer

안녕하세요. 한길아이티입니다. 현재 프로그램에서 매스기초인 경우 안정검토시 지지력검토외 활동검토는 지원하지 않고 있읍니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#205829Drawing text772007-08-17
AnsweredAAbutPier#205831When will the MASS foundation sliding check be updated?622007-08-17
AnsweredAAbutPier#205826About the foundation602007-08-17
AnsweredAAbutPier#205825Question about live load in bearing area check802007-08-17
AnsweredAAbutPier#205823Horizontal force calculation552007-08-17
AnsweredAAbutPier#205819Please merge two files732007-08-17
AnsweredAAbutPier#205812Additional pier file612007-08-17
AnsweredAAbutPier#205810Question about the number of bearings332007-08-16
AnsweredAAbutPier#205809Earth pressure calculation error in MASS foundation stability check · Currently viewing392007-08-16
AnsweredAAbutPier#205808Quantity (rebar)402007-08-16
AnsweredAAbutPier#205805Errors in pier column reinforcement detailing and coping512007-08-16
AnsweredAAbutPier#205794Pier modeling analysis error322007-08-14
AnsweredAAbutPier#205792Maximum rebar ratio check formula is applied incorrectly372007-08-14
AnsweredAAbutPier#205789Cannot enter cover thickness622007-08-14
AnsweredAAbutPier#205786About entering the unit weight of embankment material292007-08-14
AnsweredAAbutPier#205781Internal error during pile check222007-08-14
AnsweredAAbutPier#205770When applying stepped rebar to a pier462007-08-14
AnsweredAAbutPier#205764Cannot enter the number of columns in pier section dimensions372007-08-13
AnsweredAAbutPier#205763Please check the pile layout292007-08-13
AnsweredAAbutPier#205759Uploading captured images and file402007-08-13