Skip to content
AnsweredAAbutPierQ&A #2052022007-07-11 20:31 · Views 60

Question

교각 기초부 설정에서 설계검토를 누르면 말도되지않게 ng가 나옴니다.. 똑같이 입력한 다른사람은 또 ok 나오구요... 검토를 부탁합니다..

Answer

안녕하세요. 한길아이티입니다. 교각기초부설정-종방향본수가 3본인데 입력치가 D2=0,D3=2500으로 설정되있읍니다. 종방향본수가 2본으로 선택후 D2=2500으로 설정하세요. 참고로 화일을 올려드립니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#205211Abutment structural drawing402007-07-12
AnsweredAAbutPier#205202Question · Currently viewing602007-07-11
AnsweredAAbutPier#205201Abutment wing wall rebar412007-07-11
AnsweredAAbutPier#205212Please review622007-07-11
AnsweredAAbutPier#205210Abutment protection block892007-07-11
AnsweredAAbutPier#205204Question442007-07-11
AnsweredAAbutPier#205192Question522007-07-11
AnsweredAAbutPier#205190Quantity calculation for abutment protection blocks722007-07-11
AnsweredAAbutPier#205183EL calculation basis differs from general drawing402007-07-11
AnsweredAAbutPier#205191[Personal information] Update on my question?322007-07-10
AnsweredAAbutPier#205180Request to update drawing border for Korea Expressway Corporation CI change342007-07-10
AnsweredAAbutPier#205178Shear strength calculation for hollow section702007-07-10
AnsweredAAbutPier#205167aroad & apier412007-07-10
AnsweredAAbutPier#205148Hollow pier quantity omits inner closure and haunch, please check1822007-07-10
AnsweredAAbutPier#205136Cross tie error782007-07-09
AnsweredAAbutPier#205122Adjusting number of piles in transverse direction602007-07-09
AnsweredAAbutPier#205115Horizontal elastic seismic force inquiry562007-07-09
AnsweredAAbutPier#205147Please check512007-07-09
AnsweredAAbutPier#205146Dimension display error in wing wall structural drawing742007-07-09
AnsweredAAbutPier#205135Hinge values look wrong in foundation stability check742007-07-09