AnsweredAAbutPierQ&A #2037202007-05-11 17:47 · Views 23

Pile allowable stress

올려드린 화일의 말뚝 허용 휨응력과 허용 전단응력이 산출되지 않습니다. 검토부탁드립니다.

Answer

안녕하세요. 한길아이티입니다. 교대설계환경-설계선택사항-말뚝이음적용길이가 0으로 입력되어있읍니다. 적절한수치로 입력하시기 바랍니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#203773Haunch between two columns in a pi-shaped pier402007-05-15
AnsweredAAbutPier#203760Drawings are not being generated162007-05-14
AnsweredAAbutPier#203752Foundation main rebar check?222007-05-14
AnsweredAAbutPier#203751Abutment earthwork quantity report will not output62007-05-14
AnsweredAAbutPier#203749Overlapping buttons on seismic analysis screen42007-05-13
AnsweredAAbutPier#203741Is this pier type supported?172007-05-12
AnsweredAAbutPier#203739Rebar reinforcement detailing issue292007-05-12
AnsweredAAbutPier#203738Title font cannot be changed232007-05-12
AnsweredAAbutPier#203736Requesting a sample file172007-05-12
AnsweredAAbutPier#203733Re-uploading column check...252007-05-11
AnsweredAAbutPier#203726Seismic check292007-05-11
AnsweredAAbutPier#203720Pile allowable stress · Currently viewing232007-05-11
AnsweredAAbutPier#203731Combined member forces for columns222007-05-11
AnsweredAAbutPier#203724Temperature load292007-05-11
AnsweredAAbutPier#203714Seismic analysis error282007-05-11
AnsweredAAbutPier#203708How to handle transverse lateral restraint in a pi-shaped pier302007-05-11
AnsweredAAbutPier#203692In the bearing horizontal reinforcement check132007-05-10
AnsweredAAbutPier#203709Combined member forces in column check222007-05-10
AnsweredAAbutPier#203704About quantity output192007-05-10
AnsweredAAbutPier#203701Bearing specification table222007-05-10
Sign in to ask