Skip to content
AnsweredAAbutPierQ&A #2034272007-04-27 02:32 · Views 31

Pier step rebar is not generated consistently

P1과 P2의 두부보 형상이 거의 일치하는데 P2에는 단차 철근이 생성이 안됩니다. 같은 조건과 모든교각일치버튼을 해도 P2에서는 생성이 안되는데 검토부탁드립니다.

Answer

안녕하세요. 한길아이티입니다. 교각설계환경의 설계선택사항에서 단차철근적용최소높이가 상이하게 입력돠어 있읍니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#203466About earth pressure382007-05-02
AnsweredAAbutPier#203463Inquiry about pier level difference442007-05-02
AnsweredAAbutPier#203462In pier calculation592007-05-01
AnsweredAAbutPier#203450All pier conditions seem to be the same512007-04-30
AnsweredAAbutPier#203442Drawing generation error for parallel wing walls432007-04-30
AnsweredAAbutPier#203446Question on calculating horizontal loads on bridge bearings192007-04-30
AnsweredAAbutPier#203439About abutment quantity calculation452007-04-28
AnsweredAAbutPier#203437Question on abutment shear reinforcement detailing292007-04-27
AnsweredAAbutPier#203436Text disappears after viewing drawings292007-04-27
AnsweredAAbutPier#203435Abutment elevation302007-04-27
AnsweredAAbutPier#203434Suggestion on top rebar for T-shaped pier foundations422007-04-27
AnsweredAAbutPier#203427Pier step rebar is not generated consistently · Currently viewing312007-04-27
AnsweredAAbutPier#203419Shrinkage and temperature rebar312007-04-27
AnsweredAAbutPier#203415Question on reinforcement under bridge bearings302007-04-27
AnsweredAAbutPier#203412Section values differ for horizontal shear rebar (abutment parapet)452007-04-26
AnsweredAAbutPier#203410Please check drawing generation error452007-04-26
AnsweredAAbutPier#203433Stability check of mass foundations272007-04-26
AnsweredAAbutPier#203405Bearing distance is wrong based on entered expansion joint and coordinate values192007-04-26
AnsweredAAbutPier#203404Wing wall end line angle302007-04-26
AnsweredAAbutPier#203397About section properties in seismic analysis282007-04-26
Sign in to ask