Error when checking the foundation of pier 3
교각3의 모델링 해석은 돌아가는데.. 기초부 검토를 누르면 내부응용 프로그램 오류라고 뜹니다. 교각1과 단면제원이 같아서 거의 모든걸 똑같이 설정했는데.. 교각1은 이상이 없는데 교각3에서 자꾸 오류가 납니다. 확인 부탁드립니다.
Answer
안녕하세요. 한길아이티입니다. 교각설계환경-사용하중조합,계수하중조합,계수하중조합(최대편심),피복이 입력누락되었읍니다. 기둥부주철근도 함께 누락되었읍니다. 권고안 실행후 설정값을 수정하신후 기초부 검토를 누르시면 프로그램 오류가 사라집니다. 참고로 위작업을 한 화일을 올려드립니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #202866 | Error when checking the foundation of pier 3 · Currently viewing | 43 | 2007-03-23 |
| Answered | AAbutPier | #202864 | Seismic analysis modeling problem | 20 | 2007-03-23 |
| Answered | AAbutPier | #202860 | Please check the horizontal force values under earthquake | 24 | 2007-03-23 |
| Answered | AAbutPier | #202842 | Pier foundation main rebar details | 42 | 2007-03-22 |
| Answered | AAbutPier | #202840 | Request to check horizontal force under earthquake for abutment A1 | 46 | 2007-03-22 |
| Answered | AAbutPier | #202834 | Follow-up: comparison file | 78 | 2007-03-22 |
| Answered | AAbutPier | #202833 | Something seems wrong | 73 | 2007-03-22 |
| Answered | AAbutPier | #202829 | Not sure what is causing this | 57 | 2007-03-22 |
| Answered | AAbutPier | #202857 | Torch-type wall | 37 | 2007-03-22 |
| Answered | AAbutPier | #202853 | Orthogonal layout on a curved alignment (2) | 37 | 2007-03-22 |
| Answered | AAbutPier | #202847 | Entering stringers for steel box | 41 | 2007-03-22 |
| Answered | AAbutPier | #202836 | Seismic analysis does not run | 70 | 2007-03-22 |
| Answered | AAbutPier | #202835 | Orthogonal layout on a curved alignment | 59 | 2007-03-22 |
| Answered | AAbutPier | #202823 | Wing wall reinforcement drawing section extends beyond the foundation | 58 | 2007-03-22 |
| Answered | AAbutPier | #202828 | BRX file gives an error | 39 | 2007-03-21 |
| Answered | AAbutPier | #202811 | Support treatment for continuous spans | 70 | 2007-03-21 |
| Answered | AAbutPier | #202824 | Calculation report file is too large | 77 | 2007-03-21 |
| Answered | AAbutPier | #202808 | Bridge bearing error | 42 | 2007-03-21 |
| Answered | AAbutPier | #202800 | Pile cap reinforcement needs up to 4 layers | 40 | 2007-03-21 |
| Answered | AAbutPier | #202801 | Horizontal shear reinforcement detailing in pier coping | 39 | 2007-03-20 |