Skip to content
AnsweredAAbutPierQ&A #2026432007-03-13 20:27 · Views 35

Allowable stress reduction for pile splices

말뚝기초에서 말뚝이음시 허용응력감소비를 주는데 말뚝길이가 15m라면 허용응력감소비가 적용되지 말아야 하는데 15m를 포함해서 적용이 됩니다. (참조:[개인정보])

Answer

안녕하세요. 한길아이티입니다. 말뚝길이가 15m인 경우 이음1개소에 대한 허용응력 감소비 적용오류는 수정하여 오늘까지 업데이트 하겠읍니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#202680Please review dada242007-03-15
AnsweredAAbutPier#202681Please review402007-03-15
AnsweredAAbutPier#202677Error in seismic analysis modeling272007-03-15
AnsweredAAbutPier#202674Problem importing AbeamDeck brx file242007-03-14
AnsweredAAbutPier#202669Designing an abutment as mass concrete322007-03-14
AnsweredAAbutPier#202665Importing an ARoad BRX file into APier282007-03-14
AnsweredAAbutPier#202660Column main rebar error282007-03-14
AnsweredAAbutPier#202656Barrier level in abutment front view342007-03-14
AnsweredAAbutPier#202652About pier input422007-03-14
AnsweredAAbutPier#202645Bearing seat detail A362007-03-13
AnsweredAAbutPier#202643Allowable stress reduction for pile splices · Currently viewing352007-03-13
AnsweredAAbutPier#202640Wing wall reinforcement detailing612007-03-13
AnsweredAAbutPier#202638About wall and foundation reinforcement detailing322007-03-13
AnsweredAAbutPier#202634Please review912007-03-13
AnsweredAAbutPier#202626Importing an ARoad BRX file into APier452007-03-12
AnsweredAAbutPier#202617Column main rebar placement error402007-03-10
AnsweredAAbutPier#202611Seismic analysis modeling error?392007-03-10
AnsweredAAbutPier#202609Missing rebar in pier cap302007-03-10
AnsweredAAbutPier#202608About parapet wall height512007-03-10
AnsweredAAbutPier#202615Question about elastomeric bearing specifications392007-03-09
Sign in to ask