AnsweredAAbutPierQ&A #2013582006-12-08 11:11 · Views 72

Error in seismic calculation report

내진계산시 압축및전단계수가 엉뚱한치수로 출력이 돼는군요 확인요망

Answer

안녕하세요. 한길아이티입니다. 계산서에 표기되는 강성값은 교좌장치 3개를 합산한 값입니다. s2k를 확인해보시면 입력하신데로 정상적으로 고려되었습니다. NLPROP NAME=[개인정보] TYPE=Gap DOF=U1 KE= 101760 CE=0 <-- DOF=U2 KE= 285 CE=0 <-- DOF=U3 KE= 285 CE=0 <-- DOF=R1 KE= 0 CE=0 DOF=R2 KE= 0 CE=0 DOF=R3 KE= 0 CE=0 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#201425Question about the pier calculation report702006-12-13
AnsweredAAbutPier#201422Please check the calculation report302006-12-13
AnsweredAAbutPier#201421Abutment wall temperature rebar392006-12-13
AnsweredAAbutPier#201427Column critical load check682006-12-13
AnsweredAAbutPier#201426Effective length factor in column check862006-12-13
AnsweredAAbutPier#201420Confinement rebar details762006-12-12
AnsweredAAbutPier#201406Rebar ratio error542006-12-12
AnsweredAAbutPier#201401Quantity calculation looks wrong402006-12-12
AnsweredAAbutPier#201399About the moment magnification factor in column calculation442006-12-12
AnsweredAAbutPier#201393Bearing spacing372006-12-12
AnsweredAAbutPier#201392Horizontal force due to bridge bearing friction592006-12-12
AnsweredAAbutPier#201402Regarding a file with the same problem [***]162006-12-11
AnsweredAAbutPier#201384Internal program error642006-12-11
AnsweredAAbutPier#201379Longitudinal k value for a pi-shaped pier552006-12-10
AnsweredAAbutPier#201377Question about two-layer reinforcement in wing walls742006-12-08
AnsweredAAbutPier#201359Seismic calculation582006-12-08
AnsweredAAbutPier#201365Effective length factor for column check1002006-12-08
AnsweredAAbutPier#201363Follow-up question on response modification factor872006-12-08
AnsweredAAbutPier#201358Error in seismic calculation report · Currently viewing722006-12-08
AnsweredAAbutPier#201356Wind load1002006-12-08
Sign in to ask