AnsweredAAbutPierQ&A #2006152006-10-14 02:51 · Views 26

Error when checking pier pile stress

교각 p1 말뚝 응력 검토시 허용 휨응력 및 전단응력이 나오지 않아 응력검토를 할수 없읍니다. 빨리 좀 고쳐주세요...

Answer

안녕하세요. 한길아이티입니다. 교각설계환경-설계선택사항-말뚝이음 적용길이가 0으로 입력되어있읍니다. 적정한값을 입력하세요 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#200655Mild and high-strength steel not distinguished when generating abutment structural drawings282006-10-18
AnsweredAAbutPier#200654Abutment main rebar detailing error232006-10-18
AnsweredAAbutPier#200650Drawing generation error482006-10-18
AnsweredAAbutPier#200648Question about rebar details (file attached)292006-10-18
AnsweredAAbutPier#200638About direction of centrifugal load432006-10-17
AnsweredAAbutPier#200637Shoe block362006-10-17
AnsweredAAbutPier#200634Question about pier tie bars322006-10-17
AnsweredAAbutPier#200640About centrifugal load352006-10-17
AnsweredAAbutPier#200639Temperature rebar in abutment wall472006-10-17
AnsweredAAbutPier#200633Question about rebar arrangement in cast-in-place piles342006-10-17
AnsweredAAbutPier#200625Question about pier input342006-10-16
AnsweredAAbutPier#200617File review (urgent)262006-10-14
AnsweredAAbutPier#200615Error when checking pier pile stress · Currently viewing262006-10-14
AnsweredAAbutPier#200610Applying temperature load at fixed end502006-10-13
AnsweredAAbutPier#200609Error occurs in pier calculation262006-10-13
AnsweredAAbutPier#200618Checking distribution rebar ratio of wing wall352006-10-13
AnsweredAAbutPier#200601[Suggestion] Please add a table of contents page to AAbutPier reports352006-10-13
AnsweredAAbutPier#200596Follow-up on my phone call, please review252006-10-13
AnsweredAAbutPier#200599Cross beam settings in seismic analysis202006-10-12
AnsweredAAbutPier#200586Section input for seismic analysis372006-10-12