Seismic analysis error
내진해석 하면 오류가 납니다. 확인부탁드립니다.
Answer
안녕하세요. 한길아이티입니다. [일반입력]-[내진해석 단면입력]에서 단면특성이 누락되어 있습니다. I33의 값만 입력이 되어 있고, I22,k,A등이 누락되어 해석시 오류가 발생하고 있습니다. "단면상수 사용자입력"을 체크하신 후에 입력값을 넣으시고 확인하시면 이상이 없습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #197593 | Please fix error shown in the wall reinforcement detailing tab | 11 | 2006-02-09 |
| Answered | AAbutPier | #197577 | Please review seismic check | 7 | 2006-02-09 |
| Answered | AAbutPier | #197575 | Error in wind load modeling | 5 | 2006-02-09 |
| Answered | AAbutPier | #197589 | Please improve bearing seat dimension input | 16 | 2006-02-08 |
| Answered | AAbutPier | #197580 | Applying one layer instead of two for reinforcing bars under bridge bearings | 11 | 2006-02-08 |
| Answered | AAbutPier | #197567 | When up and down lines have different start points | 10 | 2006-02-08 |
| Answered | AAbutPier | #197550 | In foundation settings | 26 | 2006-02-07 |
| Answered | AAbutPier | #197549 | Wing wall reinforcement drawing | 45 | 2006-02-07 |
| Answered | AAbutPier | #197548 | Feature request | 25 | 2006-02-07 |
| Answered | AAbutPier | #197556 | Structural drawings per pier | 7 | 2006-02-07 |
| Answered | AAbutPier | #197555 | Superstructure load not applied at bridge bearings | 11 | 2006-02-07 |
| Answered | AAbutPier | #197554 | Calculated EL values look wrong | 10 | 2006-02-07 |
| Answered | AAbutPier | #197539 | Wing wall check | 28 | 2006-02-06 |
| Answered | AAbutPier | #197538 | Fonts are not displayed | 22 | 2006-02-06 |
| Answered | AAbutPier | #197536 | Questions on automatic girder placement and more | 35 | 2006-02-06 |
| Answered | AAbutPier | #197523 | ALine seems to be missing from the APier CD | 20 | 2006-02-06 |
| Answered | AAbutPier | #197518 | Entering separate alignments | 30 | 2006-02-06 |
| Answered | AAbutPier | #197516 | Seismic analysis error · Currently viewing | 22 | 2006-02-05 |
| Answered | AAbutPier | #197515 | Longitudinal step at P6 superstructure type change point is not applied | 28 | 2006-02-04 |
| Answered | AAbutPier | #197514 | Can variable sections be applied to the top and bottom of a T-shaped pier? | 44 | 2006-02-03 |