Two-layer wall reinforcement not shown in drawing

벽체 인장부 2단배근했으나 도면에 표현이 안되고있습니다 부탁드립니다

Answer

안녕하세요. 한길아이티입니다. 2단철근의 거리를 1단철근과 같은 거리로 입력을 하여 철근이 겹쳐서 표현되고 있습니다. 주철근입력시 2단철근에 대한 거리를 "200"으로 입력하시면 됩니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#197338Abutment calculation report output looks wrong92006-01-25
AnsweredAAbutPier#197331Question while checking bearing capacity132006-01-24
AnsweredAAbutPier#197327Internal application error52006-01-24
AnsweredAAbutPier#197335Temperature load is not applied182006-01-24
AnsweredAAbutPier#197326About section check142006-01-24
AnsweredAAbutPier#197323Section input and cross beam settings142006-01-24
AnsweredAAbutPier#197320PHC pile check152006-01-24
AnsweredAAbutPier#197318About shrinkage and temperature rebar512006-01-24
AnsweredAAbutPier#197314Seismic analysis error172006-01-23
AnsweredAAbutPier#197313Bearing coordinates vs. bearing pedestal location222006-01-23
AnsweredAAbutPier#197312About foundation reinforcement detailing242006-01-23
AnsweredAAbutPier#197304Two-layer wall reinforcement not shown in drawing · Currently viewing322006-01-21
AnsweredAAbutPier#197307Please check202006-01-20
AnsweredAAbutPier#197303Thanks for the quick reply, one more request592006-01-20
AnsweredAAbutPier#197297Corrections after review452006-01-20
AnsweredAAbutPier#197296Requesting a reply192006-01-20
AnsweredAAbutPier#197295Skin friction of abutment pile foundation202006-01-20
AnsweredAAbutPier#197290Please check162006-01-20
AnsweredAAbutPier#197289When analyzing column members...372006-01-20
AnsweredAAbutPier#197288Question about calculating 1/β3942006-01-20
Sign in to ask