Inertia force of surcharge soil
상재토 관성력의 작용위치에 대해서 ... [이름]님, [이름]님 부탁드립니다....^^
Answer
안녕하세요. 한길아이티입니다. 계산된 수평력의 작용위치는 기초의 하단을 기준으로 계산되었습니다. 1) Vx는 기초의 상단 (기둥하단) 2) 기초의 자중은 기초의 중심이므로 작용거리는 2.500/2 = 1.250 3) 토피는 토피의 중심이므로 2.5 + 17.500 /2 Mo = 19891.161 + 161.7x1.250 + 97.02x11.25 + 592.420x2.50 = 22665.811 tonf.m 확인해 보시고 다른 사항이 있으시면 게시판에 남겨주시기 바랍니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #196809 | Follow-up to my phone inquiry | 18 | 2005-12-17 |
| Answered | AAbutPier | #196803 | Dewatering quantity | 24 | 2005-12-17 |
| Answered | AAbutPier | #196793 | Selecting the fixed bearing point | 36 | 2005-12-16 |
| Answered | AAbutPier | #196790 | About abutment general quantities | 34 | 2005-12-16 |
| Answered | AAbutPier | #196788 | Error when printing the pier calculation report | 19 | 2005-12-16 |
| Answered | AAbutPier | #196789 | Question about member force summary values | 36 | 2005-12-16 |
| Answered | AAbutPier | #196787 | Inertia force of surcharge soil · Currently viewing | 25 | 2005-12-16 |
| Answered | AAbutPier | #196786 | Variable section not applied in the cap drawing | 20 | 2005-12-16 |
| Answered | AAbutPier | #196785 | Error when two rebar material tables are generated | 18 | 2005-12-16 |
| Answered | AAbutPier | #196783 | Pi-shaped pier | 22 | 2005-12-16 |
| Answered | AAbutPier | #196781 | Abutment and pier | 25 | 2005-12-16 |
| Answered | AAbutPier | #196777 | Slab dimension input | 10 | 2005-12-15 |
| Answered | AAbutPier | #196776 | Approach slab | 8 | 2005-12-15 |
| Answered | AAbutPier | #196775 | Rebar length calculation for two-layer pier main reinforcement | 43 | 2005-12-15 |
| Answered | AAbutPier | #196773 | Using a different diameter for bearing rebar | 8 | 2005-12-15 |
| Answered | AAbutPier | #196766 | About changing rebar dimensions | 12 | 2005-12-15 |
| Answered | AAbutPier | #196763 | Internal application error | 18 | 2005-12-15 |
| Answered | AAbutPier | #196755 | Seismic modeling error | 10 | 2005-12-14 |
| Answered | AAbutPier | #196748 | When printing the seismic calculation report | 16 | 2005-12-13 |
| Answered | AAbutPier | #196743 | Error converting to DWG after setting XREF | 13 | 2005-12-13 |