PSC box transverse configuration when modeling an abutment

psc-box횡단구성시에 거더갯수를 1개로 적용하면 슈가 2개밖에 지원이되질 않아서 거더갯수를 3개로 적용하려면 슈의 위치를 어떻게 잡아야 하나요? 그리고 거더갯수를 3개로 적용할때 각 거더의 폭을 다르게 주어야 할때는 어떻게 해야하는지요? 도면 파일첨부합니다.꼭 좀 알려주십시요. [개인정보],구조부-[개인정보]

Answer

안녕하세요. 한길아이티입니다. 받침이 3개인 경우 받침중심위치를 거더의 중심으로 하여 3개의 거더를 입력하시면 하부구조 작업은 이상이 없이 진행이 됩니다. 거더 폭원은 [교량받침 위치 입력]에서 각각 입력하실 수 있습니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#194712Wing wall reinforcement drawing182005-09-21
AnsweredAAbutPier#194704About pier bearing seat level differences422005-09-20
AnsweredAAbutPier#194705Question about separating up and down lines302005-09-20
AnsweredAAbutPier#194697Questions about several errors342005-09-16
AnsweredAAbutPier#194686Pier reinforcement drawing output error72005-09-15
AnsweredAAbutPier#194684Longitudinal variable section of pier cap202005-09-15
AnsweredAAbutPier#194678Question182005-09-15
AnsweredAAbutPier#194676Wing wall joint issue at skewed abutment202005-09-15
AnsweredAAbutPier#194695Tie rebar details for circular columns832005-09-15
AnsweredAAbutPier#194672Stability index in column checks752005-09-15
AnsweredAAbutPier#194692Addition to No. 17415242005-09-15
AnsweredAAbutPier#194688In widened bridges222005-09-15
AnsweredAAbutPier#194679Pier design using the stability index192005-09-15
AnsweredAAbutPier#194667Horizontal force on substructure with elastomeric bearings?682005-09-15
AnsweredAAbutPier#194663Two-layer rebar in compression zone of footing heel312005-09-15
AnsweredAAbutPier#194661Follow-up to phone inquiry272005-09-15
AnsweredAAbutPier#194654About dimensions in pier section drawing392005-09-14
AnsweredAAbutPier#194653Question about railway bridges402005-09-14
AnsweredAAbutPier#194650Column axial force442005-09-14
AnsweredAAbutPier#194671PSC box transverse configuration when modeling an abutment · Currently viewing252005-09-14
Sign in to ask