AnsweredAAbutPierQ&A #1945232005-09-08 22:37 · Views 10

Pier displacement values

교각부(P3)의 교각변위가 자동으로 계산되지 않습니다. 검토바랍니다.

Answer

안녕하세요. 한길아이티입니다. 수정하였습니다. 금일자 패치에 적용하도록 하겠습니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#194575About the shear check location for piers332005-09-10
AnsweredAAbutPier#194572Superstructure load application distance looks wrong402005-09-10
AnsweredAAbutPier#194565Why does an internal application error keep appearing?502005-09-10
AnsweredAAbutPier#194564Pier displacement values392005-09-10
AnsweredAAbutPier#194559Structural calculation inquiry1402005-09-09
AnsweredAAbutPier#194554[Reinforcement drawing] Pier322005-09-09
AnsweredAAbutPier#194560Elastic seismic response coefficient432005-09-09
AnsweredAAbutPier#194550Urgent: seismic modeling looks wrong332005-09-09
AnsweredAAbutPier#194540Wing wall section error and superstructure reaction error in structural calculation report142005-09-09
AnsweredAAbutPier#194538SAP does not launch automatically (SAP 7.4)382005-09-09
AnsweredAAbutPier#194535Checking pier bearing seat location272005-09-09
AnsweredAAbutPier#194532Pier coping main rebar display error?52005-09-09
AnsweredAAbutPier#194531Moment values seem wrong in wing wall design check222005-09-09
AnsweredAAbutPier#194527About pier cap beam rebar placement162005-09-08
AnsweredAAbutPier#194523Pier displacement values · Currently viewing102005-09-08
AnsweredAAbutPier#194521Please check wall-type pier292005-09-08
AnsweredAAbutPier#194519Wing wall with two-layer reinforcement?212005-09-08
AnsweredAAbutPier#194518A2 left wing wall reinforcement drawing looks wrong222005-09-08
AnsweredAAbutPier#194514Entering abutment parapet dimensions272005-09-08
AnsweredAAbutPier#194513Why the screen and input panel differ after changing alignment direction142005-09-08