Skip to content
AnsweredAAbutPierQ&A #1934512005-07-20 22:20 · Views 16

Problem with approach slab section dimensions

접속슬래브단면이 왜 이렇게 나오나요? 해결해주세요.

Answer

안녕하세요. 한길아이티입니다. 교대1의 우측날개벽이 본체 측면에 부착된 형태로 입력이 되었으나, 날개벽을 본체 측면에 부착에는 체크가 빠져 있습니다. 체크를 하신 후 접속슬래브 입력을 확인해 보시면 정상적으로 출력이 될 것입니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#193469Section appears too large302005-07-21
AnsweredAAbutPier#193464Reinforcement detailing of step rebar392005-07-21
AnsweredAAbutPier#193461During seismic analysis472005-07-21
AnsweredAAbutPier#193451Problem with approach slab section dimensions · Currently viewing162005-07-20
AnsweredAAbutPier#193443Unit question when checking hollow T-section column332005-07-20
AnsweredAAbutPier#193431Changing bearing location262005-07-20
AnsweredAAbutPier#193460RG table calculation formula892005-07-20
AnsweredAAbutPier#193446Please reply262005-07-20
AnsweredAAbutPier#193433Additional question on clothoid282005-07-20
AnsweredAAbutPier#193429Clothoid252005-07-20
AnsweredAAbutPier#193418Wing wall check does not work312005-07-20
AnsweredAAbutPier#193427Can wind load be applied as a couple load?202005-07-19
AnsweredAAbutPier#193417File for the issue discussed by phone102005-07-19
AnsweredAAbutPier#193410Program crashes when clicking column main rebar design check372005-07-19
AnsweredAAbutPier#193406Wing wall reinforcement drawing is not generated152005-07-19
AnsweredAAbutPier#193394Please review272005-07-19
AnsweredAAbutPier#193392Shear rebar detailing error in pier cap beam362005-07-19
AnsweredAAbutPier#193391Error in span configuration input and support angle input182005-07-19
AnsweredAAbutPier#193395Question about quantities242005-07-18
AnsweredAAbutPier#193389Design code for column longitudinal rebar252005-07-18
Sign in to ask