Question about pile calculation
comb2에서 전단응력이 너무 크게 나오는데 아무리 생각해봐도 왜 그런지 모르겠네요 지진시때보다 적게 나와야 되는게 아닌가 싶은데 값이 너무 튀어서 거기서 n.g가 나네요 말뚝을 않늘리고 잡을수 있는 방법이 없는지요 혹 제가 입력을 잘못했는지요 검토 부탁드립니다
Answer
안녕하세요. 한길아이티입니다. 말뚝검토시 출력된 combo2는 온도하중,건조수축이 고려된 하중조합입니다. 교각계산서를 출력하여 해석결과집계에서 확인하시면 건조수축이 가장 지배적인 하중으로 되어있습니다. 교각의 높이가 낮고 단면의 두께가 큰 경우 온도,건조수축이 가장 지배적인 하중으로 작용하게 됩니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #193274 | Wing wall drawing error | 20 | 2005-07-13 |
| Answered | AAbutPier | #193273 | Section offset from road centerline when input based on road centerline | 22 | 2005-07-13 |
| Answered | AAbutPier | #193270 | Strange output in pile calculation report | 7 | 2005-07-13 |
| Answered | AAbutPier | #193260 | Question about pile calculation · Currently viewing | 5 | 2005-07-13 |
| Answered | AAbutPier | #193246 | Question about seismic analysis | 41 | 2005-07-13 |
| Answered | AAbutPier | #193245 | Inquiry about seismic input | 39 | 2005-07-13 |
| Answered | AAbutPier | #193242 | Calculating horizontal seismic force for seismic grade 2 bridges | 16 | 2005-07-12 |
| Answered | AAbutPier | #193267 | Sole plate detail differs from "see bridge bearing specifications" | 48 | 2005-07-12 |
| Answered | AAbutPier | #193228 | Error in SAP input file for FRAME pier foundation | 21 | 2005-07-12 |
| Answered | AAbutPier | #193251 | *** Request to add section for abutment recommended design | 36 | 2005-07-12 |
| Answered | AAbutPier | #193237 | About temperature and shrinkage rebar | 8 | 2005-07-12 |
| Answered | AAbutPier | #193234 | File attached for 15901 | 4 | 2005-07-12 |
| Answered | AAbutPier | #193233 | bri file attached for *** | 7 | 2005-07-12 |
| Answered | AAbutPier | #193227 | brx file created in ARoad causes an error | 17 | 2005-07-12 |
| Answered | AAbutPier | #193215 | Error occurs, please help | 10 | 2005-07-12 |
| Answered | AAbutPier | #193224 | Question about pier analysis | 15 | 2005-07-11 |
| Answered | AAbutPier | #193217 | Checking combined member forces for pier columns | 19 | 2005-07-11 |
| Answered | AAbutPier | #193214 | Improving the design criteria for axial rebar quantity | 13 | 2005-07-11 |
| Answered | AAbutPier | #193208 | Error converting from CGS to SI units (please recheck) | 20 | 2005-07-11 |
| Answered | AAbutPier | #193203 | Entering design strength | 18 | 2005-07-11 |