Skip to content
AnsweredAAbutPierQ&A #1924512005-06-09 03:41 · Views 40

Vertical rebar in abutment wall

교대배근도(1) 단면도에서 교대벽체의 1단수직철근중 낮은쪽 철근이 교좌면 너머까지 표현이 됩니다. 검토부탁드립니다.

Answer

안녕하세요. 한길아이티입니다. 수정하였습니다. 금일자 패치에 적용하도록 하겠습니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#192470Please output the formulas292005-06-09
AnsweredAAbutPier#192468Numbers in the structural calculation report are garbled, please check342005-06-09
AnsweredAAbutPier#192467Please check the shoe specifications572005-06-09
AnsweredAAbutPier#192464Please review...252005-06-09
AnsweredAAbutPier#192451Vertical rebar in abutment wall · Currently viewing402005-06-09
AnsweredAAbutPier#192447Wing wall reinforcement detailing312005-06-09
AnsweredAAbutPier#192437When detailing wing wall reinforcement632005-06-08
AnsweredAAbutPier#192430Pier foundation check in the transverse direction (urgent)412005-06-08
AnsweredAAbutPier#192423Question about pier reinforcement detailing592005-06-08
AnsweredAAbutPier#192450Please check the attached file392005-06-08
AnsweredAAbutPier#192439Is the abutment side also possible?642005-06-08
AnsweredAAbutPier#192431Footing toe check262005-06-08
AnsweredAAbutPier#192409Allowable pullout capacity of pile foundation..1092005-06-08
AnsweredAAbutPier#192406When designing column sections402005-06-08
AnsweredAAbutPier#192403Please check this...282005-06-08
AnsweredAAbutPier#192397Approach slab section402005-06-08
AnsweredAAbutPier#192395It is a widened bridge432005-06-08
AnsweredAAbutPier#192393[Seismic analysis] Internal application error in pier seismic analysis modeling512005-06-08
AnsweredAAbutPier#192405Can the foundation size be modified?322005-06-07
AnsweredAAbutPier#192394Request402005-06-07
Sign in to ask