Check of horizontal rebar quantity in abutment foundation
현재 프로그램상 적용 수평철근 검토 전면벽과 저판에는 인장철근의 20% 이상의 배력철근을 두어야 한다.라고 있는데 이는 옹벽 기준에 있는것이 적용이 되에 있는것 같아 검토바랍니다. 연직벽 : 0.0025 BH (전면, 배면 각각 1/2) 교대흉벽 : 0.0025 BH (전면, 배면 각각 1/2) 기초 및 라멘 : 0.002 BH 인장,압축 각각1/2) 적용하는것이 타당하다고 봅니다.
Answer
안녕하세요. 한길아이티입니다. si단위일때는 2005 도로교설계기준에 맞게 적용되어 있으나, cgs일때는 아직 적용되지 않았습니다. 수정하여 패치에 적용하겠습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #192091 | Inquiry about quantity calculation | 26 | 2005-05-25 |
| Answered | AAbutPier | #192083 | Urgent, please help | 45 | 2005-05-25 |
| Answered | AAbutPier | #192082 | Question about bearing pedestal concrete | 18 | 2005-05-25 |
| Answered | AAbutPier | #192076 | Question about beam height step | 10 | 2005-05-25 |
| Answered | AAbutPier | #192075 | Something seems a bit off | 21 | 2005-05-24 |
| Answered | AAbutPier | #192070 | Seismic analysis not working | 26 | 2005-05-24 |
| Answered | AAbutPier | #192087 | Re-uploading the attachment | 25 | 2005-05-24 |
| Answered | AAbutPier | #192065 | Reinforcement detailing of abutment parapet | 58 | 2005-05-24 |
| Answered | AAbutPier | #192079 | When setting SI units | 16 | 2005-05-24 |
| Answered | AAbutPier | #192058 | Front wing wall of abutment | 21 | 2005-05-24 |
| Answered | AAbutPier | #192041 | Seismic horizontal force | 38 | 2005-05-24 |
| Answered | AAbutPier | #192040 | Span configuration input error | 5 | 2005-05-24 |
| Answered | AAbutPier | #192039 | Please review | 28 | 2005-05-24 |
| Answered | AAbutPier | #192037 | Wing walls attached to the side of the abutment | 12 | 2005-05-24 |
| Answered | AAbutPier | #192052 | Abutment section dimension input | 4 | 2005-05-23 |
| Answered | AAbutPier | #192051 | Rahmen inquiry | 30 | 2005-05-23 |
| Answered | AAbutPier | #192049 | Check of horizontal rebar quantity in abutment foundation · Currently viewing | 18 | 2005-05-23 |
| Answered | AAbutPier | #192036 | Abutment with angled wing walls (2) | 19 | 2005-05-23 |
| Answered | AAbutPier | #192034 | Please review the effective length factor calculation for columns | 26 | 2005-05-23 |
| Answered | AAbutPier | #192030 | Calculation of abutment with angled wing walls | 21 | 2005-05-23 |